Receiver unit

Advertisement

Assembly instructions | LK Receiver Unit Cq 1 (NC)
The unit is complemented with a LK Transformer
230/24V AC (article order separately)
The controlling device moves once a day in order
to prevent valves from sticking in a closed posi-
tion. If no valve movement is wanted, the function
can be disconnected by removing jumper 1 on the
thermostat. Remove the dial of the thermostat,
loosen the screws and remove the cover. Remove
jumper 1, marked BR1 on the circuit board.
Installation
A 230 Volt wall outlet should be available nearby
the receiver unit. The receiver unit may only be
installed by a suitably qualified professional ac-
cording to the wiring diagram and in accordance
with valid safety regulations. In order to achieve
protective level 2, the necessary installation mea-
surements must be taken.
Connect 230 V to terminals N and →
Coupling of controlling devices
Controlling devices are coupled between termi-
nal 9 on Cq 1 and one of the 24 Volt cables of the
LK Transformer.
If many controlling devices are to be connected,
they are coupled parallel to each other and in
series with the transformer, see wiring diagram.
Then connect the second 24 Volt cable of the trans-
former to terminal 2 on the Cq 1.
Mains AC 230V
LK Transformer
230 / 24 V AC
24 V AC
LK Actuator
Mains AC 230V
Electric wiring diagram for Cq 1
EN.33.C.74(NC).
2
LK Cq 1
2
9
N
Programming / commissioning
1. Activate the receiver unit
Always begin programming by erasing all even-
tual previous programming according to the be-
low:
• Press the "Reset" button simultaneously as
the
button.
!
• Then release the "Reset" button first, follo-
wed by
.
!
• Press reset again.
• Activate receiver unit Cq 1 by pressing once
on
.
!
A weak signal sounds and an indicating light
turns on.
2. Activate the thermostat
• Open the lid of the room thermostat and
remove the transport protection from the
batteries.
• Check that the current switch (A) is set to the
bottom position facing the heat symbol, ac-
cording to image 3
• Activate the room thermostat by holding the
lower button (B) down, press briefly on the
upper black button (C).
• When the green LED on the thermostat
lights, the lower black button (B) may be
released.
• The thermostat is now activated for pro-
gramming.
D