Mounting on a Pole

Use a pole having an outside
diameter between 1" and 1-1/4"
(25 – 31 mm).
1. Hold the mounting bracket
against the pole. Put two
U-bolts around the pole and
insert the ends through the
holes in the back of the
mounting bracket.
2. Secure the mounting bracket
using 1/4" flat washers and
1/4" hex nuts. Tighten all
four sets of washers and hex
nuts until the mounting
bracket is firmly mounted on
the pole.
3. Use the longer cable tie to
secure the coil of unused
cable to the pole; use the
8"cable ties to secure the uncoiled sensor cable to pole to prevent fraying in wind.
Mounting on a Post
1. Using four 1/4" x 1-1/2"
lag screws, attach the
mounting bracket to the
surface in the desired
location. Drill holes using
a 3/16" (5 mm) drill bit.
Use a carpenter's level
when marking the holes to
ensure that the bracket will
be level.
2. Using an adjustable
wrench or 7/16" wrench,
tighten the lag screws.
3. Use the longer cable tie to
secure the coil of unused
cable use the 8"cable ties
to secure the uncoiled
sensor cable to prevent
fraying in wind.
1/ 4" Flat Washer
Lock Washer
1/ 4" Hex Nut
Sensor Cable
1/4" x 1-1/2" Lag Screws
Sensor Cable
2-1/ 8" U-Bolts