9. Technical specifications

• Gas detected: carbon monoxide
• Dimension: 107*77*36mm
• Battery: 3xAA LR6 (capacity: 3 years)
• Low battery warning
• Battery life: 3 years
• Operating conditions:
o Temperature: -10°C to +45°C
o Humidity: 0-93%
• Standby current: <30uA
• Alarm current: <65mA
• Alarm: >85dB (3m from device)
• Display concentration range: 10-550PPM
• Power indicator: Flashes approximately every 45 seconds.
• Product Lifetime: 10 years
• Box content: Co detector + manual + mounting kit