Download Print this page

Frigidaire FFU14FK1DW3 Service Data Sheet

Automatic defrost upright freezer

Advertisement

Quick Links

ELECTRICAL CIRCUIT
Power
See Diagram
Blk
Timer
Yel
Compressor
Blu
Cold
Control
Or
Defrost
Thermostat
Brn
Door
Interior Light
Switch
Power On
Red
Temp Warning
Alarm
Sensor
Alarm
Buzzer
Off
On
EC41
SYSTEM SCHEMATIC
Condenser
High Side
Process
Drier
Tube
Capillary
Low Side Process Tube
SS98
IMPORTANT
If any green grounding
Wh
wires are removed dur-
ing
servicing,
must be returned to
their original position
Fan
and properly secured.
Defrost
Heater
WIRING DIAGRAM
Run
Capacitor
Compressor
Controller
Evaporator Coil
Suction
Tube
Compressor
Discharge
IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
they
should not attempt to make repairs
due to the possibility of electrical
shock. Disconnect power cord
before servicing.
INSTALLATION
This product is designed for "free standing installation only" and three inches
of clearance must be provided on all sides of the freezer for air circulation.
The freezer should be positioned on a solid floor, and the front of the
cabinet should be raised just enough to provide easy door closure when
open about half way.
Yel
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
Wh
TEMPERATURE CONTROL
6.2°F cut in, -5.7°F cut-out @ number 1 setting.
C10
DEFROST CONTROL
An automatic 30 minute defrosting period is initiated after every 12 hours of
compressor running time. During the defrosting period a thermostat will
switch the defrost heater off after the frost on the evaporator has melted. The
defrost thermostat closes at 10°F and opens at 50°F.
PERFORMANCE (Control at number 1 setting)
Room Ambient
Freezer Compartment Temperature
Percent Running Time
*Wattage Range (Last
Suction Pressure (Cut-in, cut-out), PSIG
High Side Pressure (Last
Specifications subject to change without notice.
*For complete performance data by model refer to service manual.
216857900
SERVICE DATA SHEET
AUTOMATIC DEFROST
UPRIGHT FREEZER
70°F
5 to 12°F
30-40%
1
of cycle)
110-125
3
14-0
1
of cycle), PSIG
110-125
3
90°F
5 to 12°F
45-55%
115-130
14-0
150-165
PD645

Advertisement

loading

Summary of Contents for Frigidaire FFU14FK1DW3

  • Page 1 This product is designed for “free standing installation only” and three inches of clearance must be provided on all sides of the freezer for air circulation. The freezer should be positioned on a solid floor, and the front of the...
  • Page 2 CIRCUIT ÉLECTIQUE Courant électrique Voir schéma Noir Blanc Minuteur Jaune Compresseur Bleu Commande de froid Ventilateur Orange Chauffage Thermostat de dégivrage de dégivrage Brun Interrupteur Lampe de porte intérieure Condensateur Témoin fonct. allumé Rouge Contrôleur du Avertissement temp. Capteur compresseur de l'alarme Alarme Sonnerie...