INSTALLER’S & OWNER’S MANUAL INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Designed For Basement and Crawl Space Dehumidification Includes installation, operating and safety instructions, warranty information Read and save these instructions www.BasementSystems.com For product information go to: www.SaniDryDehumidifier.com Rev 2012-01...
9. Maintenance ..................5 indoor residential setting where dehumidification is desired. The 9.1 Air Filter ..................5 SaniDry CX is not intended to be used in indoor pool rooms. 9.2 Cleaning and Replacement ............5 9.3 Removing Filters ............... 6 This unit is designed to operate in temperatures between 40°F...
15-Amp circuit. Use of a ground fault circuit interrupter (GFCI) protected circuit is recommended. 5. insTallaTion loCaTion Figure 2: The SaniDry CX can be installed in a variety of locations to meet Insert leveling the owner’s needs, but should be installed in the area to be feet in locations dehumidified.
In order to use a separate condensate pump, the SaniDry CX will need to be raised up on blocks in order to maintain the gravity feed out of the SaniDry CX and into the condensate pump for proper condensate removal.
5% RH above the dial set point. Dehumidification will stop when 9.1 air Filter The SaniDry CX ships with a standard MERV-11 the RH drops 5% below the set point. 65% 1” pleated fabric filter and a 1/4” aluminum framed pre-filter installed.
For service call your local basement systems dealer. 11. TeCHniCal desCriPTion The SaniDry CX uses a refrigeration system similar to an air conditioner’s to remove heat and moisture from incoming air and add heat to the air that is discharged. Hot, high - pressure refrigerant gas is routed from the compressor to the condenser coil.
SaniDry CX INSTALLER'S AND OWNER'S MANUAL SaniDry CX SERVICE PARTS LIST • To order, contact your local Basement Systems Dealer 12 TroublesHooTing accessory name qTy(PC) specifications/Material “Fan only runs when dehumidifier is on” mode: Pre-filter Aluminum,mesh,foam blower and compressor do not run.
Exhaust Duct Ring is seated all the way down in slots. exhaust end slots in cover for exhaust duct ring optional equipment To order optional equipment for the SaniDry CX, call 2. Connect the flexible duct hose to the Exhaust Duct Ring. 1-800-640-1500 Connect flexible hose 3.
Limited Warranty. Basement Systems, Inc. (“BSI”) warrants as Limitation of Liability. IN NO EVENT SHALL BSI, IN CONNECTION follows: (i) the SaniDry CX dehumidifier (“Product”) will be free of WITH THE DESIGN, SALE, INSTALLATION, USE, REPAIR, material defects in workmanship or materials for a period of thirty REPLACEMENT OR PERFORMANCE OF ANY PRODUCT, COMPONENT, months following the date of manufacture on the cabinet label.