ELECTRICAL CIRCUIT
Power
Blk
See Diagram
Yel
Compressor
Red
Temp Warning
Red
Cold Control
Alarm
Buzzer
Alarm Sensor
Off
On
Red
Door
Switch
Power On
EC69
SYSTEM SCHEMATIC
Condenser
High Side
Process Tube
Drier
Capillary
Low Side Process Tube
SS1
IMPORTANT
If any green grounding
Wh
wires are removed dur-
ing
servicing,
must be returned to
their original position
and properly secured.
WIRING DIAGRAM
Run
Interior
Capacitor
Light
Compressor
Controller
Evaporator
Compressor
Suction
Tube
Discharge
IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
they
should not attempt to make
repairs due to the possibility of
electrical
shock.
power cord before servicing.
INSTALLATION
This product is designed for "free standing installation only" and three
inches of clearance must be provided on all sides of the freezer for air
circulation.
The floor or mounting surface should be level and capable of supporting the
weight of the freezer when it is fully loaded.
Yel
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Wh
Refer to serial plate.
C10
TEMPERATURE CONTROL
14.0°F cut in, 0°F cut-out @ number 1 setting.
PERFORMANCE (Control at number 1 setting)
Room Ambient
Freezer Compartment Temperature
Percent Running Time
*Wattage Range (Last
Suction Pressure (Cut-in, cut-out), PSIG
High Side Pressure (Last
Specifications subject to change without notice.
*For complete performance data by model refer to service manual.
216803900
SERVICE DATA SHEET
CHEST FREEZER
Disconnect
70°F
5 to 12°F
30-40%
1
of cycle)
85-100
3
15-0
1
of cycle), PSIG
95-110
3
90°F
5 to 12°F
40-50%
95-110
15-0
140-155
PD641

Advertisement

loading

Summary of Contents for Frigidaire FFC15C3AW0

  • Page 1 INSTALLATION This product is designed for “free standing installation only” and three inches of clearance must be provided on all sides of the freezer for air circulation. The floor or mounting surface should be level and capable of supporting the Capacitor weight of the freezer when it is fully loaded.
  • Page 2 CIRCUIT ÉLECTRIQUE Courant électrique Noir Blanc Voir schéma Jaune Compresseur Rouge Avertissement temp. Capteur de Rouge Alarme l'alarme de Sonnerie Arrêt Marche la commande de froid Rouge Interrupteur Lampe Condensateur de porte intérieure de marche Contrôleur du compresseur Témoin fonct. allumé FEC69 SCHÉMA DU SYSTÈME Condenseur...