E90-DTU(400SL30P)User manual
When users use the host computer to configure the relay mode, they need to pay special attention. Because each
parameter in the host computer is a decimal display mode, the module address and network ID need to be converted
when filling in. For example, if the network ID entered by the transmitting end A is 02 and the network ID entered by the
receiving end B is 10, when the relay end R sets the module address, it will convert the hexadecimal value 0X020A to a
decimal value 522 as the relay end R to fill Module address. That is, the module address value to be filled in by the relay
rat this time is 522.