Rs232; Rs485 - Ebyte E90-DTU Manual

Hide thumbs Also See for E90-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd.
diameter , 2.5mm diameter ;
Also users can choose the VCC and GND terminal power supply from ② , both are optional;
It can also be powered by ⑤ VCC terminal and ④ GND terminal, just choose any one of the power supply modes;
8 ~ 28V DC power supply, it is recommended to use 12V or 24V DC power supply for E90-DTU.

4.2 RS232

The E90-DTU can be connected to the device via RS-232 using the standard DB-9 interface.

4.3 RS485

E90-DTU can use ②485_A terminal and ③485_B terminal to connect RS-485 A terminal and B terminal of the
device respectively.
Pin NO.
Definition
2
485_A
3
485_B
4
GND
5
VCC
Note: When the radio is connected to multiple devices, communication is not smooth, but it is not the case with a single
device. Please try to connect a 120Ω matching resistor in parallel between the 485_A terminal and the 485_B terminal.
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co., Ltd
Function
RS-485 interface, A interface
RS-485 interface, B interface
Crimping power interface,
negative
Crimping power interface,
positive
E90-DTU(400SL30P)User manual
Description
The RS-485 interface A is connected to the device
interface A
The RS-485 interface B is connected to the device
interface B
The power supply negative pole is connected to the
system ground and the housing
8 ~ 28V DC, recommended 12V or 24V
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

400sl30p

Table of Contents