Advertisement

E N
O p e r a t i n g i n s t r u c t i o n s
Y H C O M F O R T C o n t r o l P a n e l
Y H C o m f o r t

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the YH COMFORT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YILKAR YH COMFORT

  • Page 1 O p e r a t i n g i n s t r u c t i o n s Y H C O M F O R T C o n t r o l P a n e l Y H C o m f o r t...
  • Page 2: Table Of Contents

    C o n t e n t s 1.Instruction ................... 4 1.1 Warranty and liability ............4 2.Safety ..................3.Overview ..................5 3.1 Control Panel ..............5 3.2 Buttons ................5 3.3 Symbols ................6 3.4 Heating level selection ............6 3.5 Operation screens ............
  • Page 3 7.5.2 Altitude Setting ..........19 7.5.3 Screen time setting .......... 20 7.5.4 Setting reset ............. 20 7.5.5 Info ..............20 8.Cleaning ..................21 9.Error Statement and reset ............21 10.Error codes ................22 11.Technical information ............... 28...
  • Page 4: Instruction

    1 . I n t r o d u c t i o n To fully enjoy the comfort of your Yılkar heater, please read this user manual carefully. If you have additional questions regarding assembly or operation, please contact your specialist dealer or Yılkar service.
  • Page 5: Overview

    3 . O v e r v i e w Important ! When you first open your control panel, set the day and time in the "Time Setting" menu. see. p. 18 3 . 1 C o n t r o l p a n e l Back and off button Right selection button Enter and confirm button...
  • Page 6: Symbols

    3 . 3 S y m b o l s Program menu Ventilation menu Heating menu Settings menu Attention Fan speed 1-2-3 Add a timer program Delete a timer program Edit a timer program Heating is active Timer is active Altitude mode is active Ventilation is active Main menu is active...
  • Page 7: Operation Screens

    3 . 5 O p e r a t i o n s c r e e n s H e a t i n g o p e r a t i o n s c r e e n Control of heating level Control of set tempature Control of heating duration...
  • Page 8: Heating Operation

    4 . H e a t i n g o p e r a t i o n H e a t i n g s t a r t a n d s t o p Heating starts at the factory settings. Set: 25 °C Power: Maximum Duration: 1 hour To change it in the settings menu, see.
  • Page 9: Ventilation Operation

    5 . V e n t i l a t i o n o p e r a t i o n F a n s t a r t a n d s t o p The fan starts at factory settings. Power: 2nd Stage Duration: 1 hour To change it in the settings menu, see.
  • Page 10: Timer Program

    6 . T i m e r p r o g r a m 6 . 1 . S e t a h e a t i n g t i m e r Time and current day are set. The heater is off. Main menu "Timer" menu element is selected. The timer setting menu is entered by pressing the confirm button in the main menu.
  • Page 11 If the confirmation button is pressed, the change is saved and the selection switches to the "Stop Time" setting. You can set the stop time in hours and minutes with the arrow buttons. Attention! You cannot set the stop time earlier than the start time. In this case, the warning sign appears in the upper right and if you press "OK", it returns to the "Stop time"...
  • Page 12: Set A Ventilation Timer

    6 . 2 . S e t a v e n t i l a t i o n t i m e r Time and current day are set. The heater is off. Main menu "Timer" menu element is selected. The timer setting menu is entered by pressing the confirm button in the main menu.
  • Page 13 If the confirmation button is pressed, the change is saved and the selection switches to the "Stop Time" setting. You can set the stop time in hours and minutes with the arrow buttons. Attention! You cannot set the stop time earlier than the start time. In this case, the warning sign appears in the upper right and if you press "OK", it returns to the "Stop time"...
  • Page 14: Timer Editing

    6 . 3 . T i m e r e d i t i n g Time and current day are set. The heater is off. The timer you want to change is selected in the timer menu. By pressing the confirm button in the timer menu, the timer setting menu is entered.
  • Page 15: Timer Installation Errors

    6 . 5 . T i m e r i n s t a l l a t i o n e r r o r s 1. The time interval conflict Attention! When installing the timer, more than one program cannot be set to the same time period in the same day.
  • Page 16: Settings

    7 . S e t t i n g s 7 . 1 G e n e r a l i n f o r m a t i o n There are 4 setting elements in the settings menu. These; Quick start setting Time and day setting Language setting...
  • Page 17 If the confirm button is pressed, the selection switches to the "Power" setting. You can adjust the power with the arrow buttons. If the confirmation button is pressed, the change is saved and the selection switches to the "Time" setting. You can select the time with the arrow buttons.
  • Page 18: Time And Day Setting

    7 . 3 T i m e a n d d a y s e t t i n g The 24-hour slice is applied as the time zone. The "Time Setting" menu item is selected in the settings menu. If the confirmation button is pressed, the selection changes to the "Hour"...
  • Page 19: System Settings

    7 . 5 S y s t e m s e t t i n g s Main menu "System Settings" menu element is selected. System settings menu is entered by pressing the confirmation button in the main menu. 7 . 5 . 1 U n i t S e t t i n g The "Unit"...
  • Page 20: Screen Time Setting

    7 . 5 . 3 S c r e e n t i m e s e t t i n g The "Screen time" menu element is selected in the settings menu. If the confirmation button is pressed, the selection changes to the "Screen time"...
  • Page 21: Cleaning

    8 . C l e a n i n g Please use only a soft, lint-free cloth for cleaning the control panel. Moisture should not get into the body. Do not use glass cleaners, household cleaners, sprays, solvents, alcohol-containing or abrasive cleaners.
  • Page 22: Error Codes

    1 0 . E r r o r c o d e s E 01 : Glow Plug Open Circuit Cause: The cable may be cut or the socket may be disconnected. The glow plug may be defective or broken. Device Response: When the device sees the error, it wants to switch to stop mode.
  • Page 23 E 04 : Fuel Pump High Current Cause: Cable may be cut or short-circuited. Device Response: If the system detects an error while in the stop mode, the system will not operate and an error will appear on the screen. If the pump is short-circuited while the system is running, the system will likely go into stop mode by cooling to detect that the flame has gone out (E19) or that the combustion has not started (E15).
  • Page 24 E 07 : Indoor Temperature Sensor Open Circuit Cause: The cable may be cut or the socket may be disconnected. The indoor temperature sensor may have failed. Device Response: When the device sees the error, it wants to switch to stop mode. Troubleshooting: * Check the internal temperature sensor cable and sockets.
  • Page 25 E 11 : Flame Monitoring Sensor High Current Cause: Cable may be cut or short-circuited. Device Response: When the device sees the error, it wants to switch to stop mode. If the system is hot, it will operate cooling mode before stopping. Troubleshooting: * Check the flame monitoring sensor cable and sockets.
  • Page 26 E 14 : Low Voltage Failure Cause: The voltage drops below 21 volts for 24-volt devices and less than 10.5 volts for 12-volt devices, and the device detects a low voltage failure if the supply voltage is present for more than 20 seconds.
  • Page 27 E 17 : Control Unit Communication Failure Cause: Deformation may occur in the cables that the device communicates with the control unit. There may be a failure in the YHC or control panel. Device Response: When the device detects this error, it will go into stop mode by cooling if it is working.
  • Page 28: Technical Information

    The installation instructions must be read and followed carefully before installing the heater and operating the device. Regulations will be invalid and YILKAR will not take any responsibility if improper installation or work is done or determined to be done.
  • Page 32 Vehicle Heating Cooling and Ventilation Systems Phone : +90 224 215 53 28 (pbx) : +90 224 215 99 24 Address : Küçükbalıklı Mah. 580.Sok No:6 Osmangazi / BURSA / TURKEY w w w . y i l k a r k l i m a . c o m...