Page 1
Installation, Operation and Maintenance Guide Matterhorn 1000/1002 OUR MISSION IMPORTANT To improve health and wellness by actively restoring indoor air Save this Document to its pure, natural state where no pollution or contaminants for Future Reference & AtmosAir.com exist, while reducing energy use and emissions in the process.
Page 2
3,000 VAC. ■ Installation of AtmosAir equipment is not to be performed in areas with extreme conditions such as extreme heat or cold, or where water or condensing moisture can impact the system.
Page 3
Installation, Operation & Maintenance Guide Matterhorn 1000/1002 Disclaimer: The air purification technologies provided by Clean Air Group are intended to improve indoor air quality. They are not intended as a replacement for reasonable precautions aimed at preventing the transmission of contaminants, airborne or otherwise.
3. Location and Orientation: Install the unit downstream access panel for servicing should be installed over the AtmosAir of filters, coils, and fans with the ionization tubes vertical equipment. Contact AtmosAir Sales for A.W.E. specifications.
Installation, Operation & Maintenance Guide Matterhorn 1000/1002 Duct Cut-Out and Quick Change Plate Procedure PLEASE READ ENTIRE PROCEDURE BEFORE STARTING: Notes: ■ Utilize the Quick-Change Plate (Q.C.P.) in thin ducts, fiberboard ducts or where relatively frequent dismounts may occur, however the Q.C.P. can be used in any duct mounting application.
■ Field-install a power plug outlet or junction box within 8 feet (2.5 m) of the unit(s). ■ Each Matterhorn 1000/1002 series unit is typically shipped with a 10-foot power cord with a C-30 connector on one end and a 3-prong NEMA 5-15 plug on the other end. The...
Installation, Operation & Maintenance Guide Matterhorn 1000/1002 03 FIELD WIRING DIAGRAM AIRFLOW SAMPLING TUBE INSERT 6" INTO AHU OR DUCT AFTER FAN, AIRFLOW INTO TUBE END. SILICONE IN PLACE 1/4" POLYETHYLENE TUBING LID IS REMOVABLE MATTERHORN LEAVE OPEN TO 1000-1002...
A tube replacements once every two years as the production bi annual tube replacement is required. Your local AtmosAir efficiency slowly declines over time due to the stress caused dealer can provide you with a service contract.
Installation, Operation & Maintenance Guide Matterhorn 1000/1002 06 TROUBLESHOOTING In the event that the system is not functioning, follow these 7. If physical inspection has not revealed the cause of failure, steps IN ORDER: one may carefully observe the tubes as the ionization system is turned on to determine whether arcing is 1.
07 MECHANICAL INSTALLATION ILLUSTRATIONS Above: Matterhorn 1002 Ionization Above: Matterhorn 1000 Ionization unit. Here you will see there is one Ionization unit. Here you see there are Tube installed towards the center of the device. (This should always be installed with the tube closest to the center of the unit.) The remaining unused ‘Spring...
Installation, Operation & Maintenance Guide Matterhorn 1000/1002 08 EXPLANATION OF TECHNOLOGY AtmosAir Solutions’ ™ mission is to bring and restore every indoor environment the same clean and pure quality air that is typically found at higher mountain elevations. AtmosAir’s unique and proven air purification process significantly reduces mold, controls the spread of bacteria and airborne viruses, and reduces airborne particles that evade normal filtration solutions.
Clean Air Group or the dealer where you purchased the unit. Disclaimer: The air purification technology provided by AtmosAir is intended to improve air quality. It is not intended to replace reasonable precautions to prevent the transmission of airborne contaminants. Customer, its employees, invitees and all persons having access to the serviced premises should comply with all applicable public health laws and guidelines issued by federal, state and local governments and health authorities such as the Centers for Disease Control and Prevention (CDC).