Download Print this page

Meech 200 Series Operating Manual

Ionising blower
Hide thumbs Also See for 200 Series:

Advertisement

Quick Links

Operating
Manual
Model 225
Ionising Blower

Advertisement

loading
Need help?

Need help?

Do you have a question about the 200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Meech 200 Series

  • Page 1 Operating Manual Model 225 Ionising Blower...
  • Page 3: Table Of Contents

    Products shown in this document may be covered by one or more patents, patents applied for and/or registered designs and/or trade marks. For further information please refer to our Head Office or visit www.meech.com. © Meech Static Eliminators Ltd., 26.10.2017...
  • Page 5: Introduction

    Shipping claims must be made by the consignee to the delivering carrier. Meech Static Eliminators should be notified of any claims.
  • Page 6: Installation And Use

    Installation and Use The Model 225 Ioniser is designed for under-shelf mounting. Swivel mounting brackets allow the unit to be rotated and clamped so that the ion airstream can be directed over the required work bench area. The mains supply is connected to the ioniser via its IEC ( the mains supply must be elctrically grounded / earthed.) socket located on the rear of the blower.
  • Page 7: Indicator Led's

    Indicator LED’s 1. Power On LED (Green) This illuminates when the unit is switched ON and indicates that an electrical supply is present within the Ioniser. 2. (a, 2b, 2c) Ion Balance Indicator LED’s ( Red, Green, Red) This array of three lamps indicates the ion balance state. Under normal operating conditions only the middle (Green) lamp will be illuminated.
  • Page 8 Ion Balance Adjustment 5.Ion Balance Adjustment POT Balance adjustment is achieved via the recessed potentiometer. Turning this potentiometer will increase or decrease the +ve or –ve ion output resulting in a change in ion balance at the target surface . Fan Speed Selection 6.
  • Page 9 9. RJ45 Socket This socket provides output signals so that the Model 225 may be monitored remotely by a Factory Management System (FMS) or similar. ( see specification for wiring instructions). 10.Calibration trim POTS Used for factory calibration Alarm Function / Selection ( found on blower PCB) 11.
  • Page 10: Periodic Maintenance

    If the pins are found to be worn and require replacement, the pins should be removed using a pair of round nose pliers and replacements fitted. Replacement pins are available from Meech. Calibration This should be completed by Authorised Personnel only The Model 225 has been factory calibrated in accordance with ANSI-EOS/ESD- S3.1-1991.
  • Page 11 Normal Operational Mode - Ion Balance Adjustment. (A suitable charge plate monitor is required - 6” Charge plate , 1000 to 100V decays). In normal operational mode (jumper on PCB set to NORM) ion balance can be adjusted using the Ion Balance Control POT on the face of the blower. Insert a POT adjuster tool through the hole and rotate the ion balance control POT until zero volts is displayed on the charge plate monitor.
  • Page 12 Specification Dimensions : A225-0600 100 x 600 x 200 ( H x L x D) : A225-1000 100 x 1000 x 200 : A225-1200 100 x 1200 x 200 Weight : A225-0600 4.6 Kg : A225-1000 8.2 Kg : A225-1200 10.5 kg Enclosure : Powder Coated steel...
  • Page 13: Repairs And Warranty

    OFF / ON Repairs And Warranty The Ioniser is warranted by Meech Static Eliminators Ltd to the original purchaser against defects in material and workmanship for one year after purchase. Should any malfunction occur, please return the Ioniser directly to Meech or your distributor.
  • Page 14 Your Ioniser has been designed to minimise the effects of localised static charges. If your processing involves generation of considerable static charges you may need more powerful equipment. Meech Static Eliminators Ltd has available a complete line of Ionising Blowers, Air Guns, Bars and Overhead Room Systems to meet all your Static Elimination requirements.
  • Page 16 Meech International Meech Static Eliminators USA Inc Meech Elektrostatik SA Meech CE 2 Network Point 2915 Newpark Drive Kaiserbaracke 166 Gábor László utca 2 Range Road, Witney Norton, OH 44203 B-4780 St.Vith Budapest 1041 Belgium Hungary OX29 0YN, UK Tel: +44 (0)1993 706700 Tel: +1 330 564 2000 / 1 800 232 4210 Tel.: +49 (0)6555 3733 399...

This manual is also suitable for: