Specification And Parameter; Limit Parameter; Operating Parameter - Ebyte E30-400M20S Quick Start Manual

Si4463 433/470mhz 100mw spi wireless module
Hide thumbs Also See for E30-400M20S:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd

2 Specification and Parameter

2.1 Limit Parameter

Main parameter
Power supply(V)
Blocking power(dBm)
Operating temperature(℃)

2.2 Operating Parameter

Main parameter
Operating voltage(V)
Communication level(V)
Operating temperature(℃)
Operating frequency(MHz)
TX current(mA)
Power
Consump
RX current(mA)
- tion
Sleep current (μA)
Max TX power(dBm)
Receiving sensitivity(dBm)
Main parameter
Reference distance
Modulation
Communication Interface
Package
Interface method
Size
Antenna
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Performance
Min
Max
1.8
3.6
-
10
-40
+85
Performance
Min
Typical
1.8
3.3
-
3.3
-40
-
425
-
80
100
-
16.5
-
2.5
19
20
-113
-115
Description
Test condition:clear and open area, antenna gain: 5dBi,
2.5Km
antenna height: 2.5m,air data rate: 1kbps
GFSK
SPI
Max. rate 10Mbps
SMD
Stamp Hole
20*14mm
IPEX/STAMP
50 ohm impedance
Voltage over 3.6V will cause permanent damage to
module
Chances of burn is slim when modules are used in
short distance
Industrial grade
Max
3.6
3.3 V ensures output power
-
For 5V TTL, it may be at risk of burning down
+85
Industrial grade
525
130
Instant power consumption
-
-
21
-116
Air data rate is1kbps
Remark
-
-
-
-
E30-400M20S User Manual
Remark
Remark
-
-
-
-
5

Advertisement

Table of Contents
loading

Table of Contents