Cut the loop of grey wire from the black module on DTC main harness (Figure 61).
Route the following wires into the engine compartment via a grommet in the
firewall*:
*White 16 AWG wire with bullet connector from the control module (clutch
wire).
*Grey cable with the green connector from the control module (temperature
sensor).
*Red wire from the control module (constant power). Cover all of the engine
compartment wires with plastic loom.
Engine Bay Connections
Route the grey cable and white wire running from the control module along the
OEM wiring harness, and around the degas bottle.
Crimp the supplied fuse holder to the red wire running from the control module.
Ensure the fuse holder is installed as close to the power source as possible.
Connect the other end of the fuse holder to the positive battery terminal.
Connect the green connector on the grey cable to the matching connector on
the compressor.
Connect the bullet connector on the white wire to the matching connector on
the compressor.
Connect the 2 pin connector on the pressure switch harness into the pressure
switch.
Connect the ring terminal on the green wire with yellow stripe to a good ground.
Route the grey 18 AWG wire to the WHASP Tank.
VMAC - Vehicle Mounted Air Compressors
VMAC Technical Support: 888-241-2289
VMAC Knowledge Base: kb.vmacair.com
Cut loop
Figure 61 — Disable pull up harness