MAINTENANCE
Caution: To avoid personal injury, disconnect power to the light and allow the unit to cool down before
performing maintenance.
Warning: No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void
the warranty.
1. Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine
checks to be made on a yearly basis. Frequency of use and environment should determine this. It is
recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B:
Recommended practice for Electrical Equipment.
2. The lens should be cleaned periodically as needed to ensure continued photometric performance.
Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid
cleaner.
3. Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or
contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.
4. Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.
MOUNTING:
Unless otherwise specified, our standard, most popular configuration is the bracket end mounting shown enlarged
below. We also offer a pendant mount for those needing to suspend the fixture away from the ceiling surface (i.e.
suspend from pipe or conduit). Additional mounting configurations can be customized to meet the requirements on the
application. Please contact us for special mounting configurations.
STANDARD SURFACE MOUNT BRACKETS:
Each L bracket is cinched to the bracket mounting peg on each side of the light. The angle of the bracket is set by
tightening two bolts on either side of the bracket. The bolts act as a set screw. The bracket itself is mounted via a
single bolt hole at the top the bracket. There are two brackets. Once the brackets are mounted to a surface (ceiling,
floor or wall), the light fixture can be pivoted by loosening the that hold the bracket to the mounting peg. This fixture
allows 45° of pivot from the 90° point.
WIRING:
We strongly encourage a licensed electrician install this product
where weatherproofing may be required. Universal voltage driver permits operation at 100V - 277V AC, 50 or 60Hz
except those factory ordered with low voltage 11V to 25V AC/DC.
Warning: Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown
in the diagram 
Secure each pair of wires according to the diagram. Utilize a junction box or
similar
device
and
connections if installed in a location where water may come in contact with the
unit. Ensure the unit is properly grounded and that wiring is done according to
all local and national electrical/building codes.
Larson Electronics, LLC
take
precautionary
steps
Phone: (800) 369-6671
, in all locations especially in outdoor areas
for
weatherproofing
all
Fax: (903) 498-3364
HAL-48-2L-LED-BMSW-G2-OPQ
www.larsonelectronics.com
2 of 3

Advertisement

loading

This manual is also suitable for:

Hal-48-2l-led-bmsw-g2-opq