7.1.1.
Ensure the machine is unplugged from the power supply.
7.1.2.
Remove the motor housing and with the raised rim uppermost fit the filter cartridge tube down over the filter basket and push fully
home. Place the locking disc onto the top of the filter and turn the locking bar until the latch drops into the slot in the top of the filter
cage. Continue turning clockwise until the filter is fully locked down.
7.1.3.
Reposition the motor housing onto the drum body, and clip in place.
7.1.4.
Insert the larger end of the flexible hose into the front inlet on the container and lock in place. Push the required attachment, when
applicable, onto the free end of the hose.
7.1.5.
Plug into the power supply.
7.1.6.
With the selector switch "A" in position , switch "B" to the 'On' (position 'I'). See 6.2 for introduction of a power tool.
7.1.7.
When you have completed vacuuming, press the switch "B" to 'Off' (position 'O').
fig.3
WARNING! Ensure you read, understand and apply Section 1 'Safety Instructions'. Reminder: DO NOT vacuum hazardous
substances, hot ashes or embers.
7.2.
CATEGORY M CONTAINMENT BAG FILTER. Never reuse the bag always replace it.
7.2.1.
Ensure the machine is unplugged from the power supply.
7.2.2.
Remove the motor housing. Insert the Category M bag into the drum and fit the plastic socket "x" over the drum internal "y" spigot
(fig.4).
7.2.3.
Reposition the motor housing onto the drum body, and clip in place.
7.2.4.
Insert the larger end of the flexible hose into the front inlet on the container drum. Push the required attachment, when applicable,
onto the free end of the hose.
7.2.5.
Plug into the power supply.
7.2.6.
With the selector switch "A" in position
7.2.7.
When you have completed vacuuming, press the switch "B" to 'Off' (position 'O').
7.2.8.
When the bag is 3/4 full or vacuuming efficiency drops, remove the bag and seal the opening with the attached plug. Dispose of the
bag in accordance with local regulations. DO NOT re-use.
7.2.9.
Avoid using the bag for sharp or damp materials.
8. WET VACUUMING
The Category M filter is NOT for liquids. Vacuuming liquids is only allowed where there is no chance that dust will be sucked up.
WARNING! Ensure you read, understand and apply Section 1 'Safety Instructions'. Reminder: Remove the plug from power supply
before opening unit. DO NOT vacuum solvents, explosives, inflammable and/or hazardous liquids such as petrol, oil, spirits, paint,
thinners, acids etc.
8.1.
Ensure the machine is unplugged from the power supply. Make sure the drum is clean and free from dust and dirt.
8.2.
Remove the cartridge filter and fit a foam filter (NOT suitable for Class M dust) over the filter basket. Replace the motor housing onto
the container fig.5.
8.3.
Fit the crevice nozzle to the flexible hose.
8.4.
Ensure the switch "B" is 'Off' (position 'O') before plugging into the power supply.
8.5.
With the selector switch "A" in position , switch "B" to the 'On' (position 'I'). See 6.2 for introduction of a power tool.
NOTE:
To vacuum large quantities of liquid, from a sink or tank etc, DO NOT immerse the nozzle completely in the liquid, leave a gap (fig.6)
at the top of the nozzle opening to allow an air inflow. The machine is fitted with a float valve which stops the suction action when the
tank has reached its maximum capacity. The user will notice an increase in motor speed. When this happens, turn off the machine,
disconnect from power supply, remove the head from the container and empty the liquid into a suitable receptacle or drain. To continue
vacuuming, refit the head and proceed.
After wet vacuuming, turn the machine off and unplug from the power supply. Empty the container, clean and dry the inside and
outside before storage.
Remember! After wet vacuuming the foam filter must be removed and a cartridge filter must be fitted before dry vacuuming again.
WARNING! Not designed for liquid storage. Always empty liquids after use before storing.
fig.5
© Jack Sealey Limited
, switch "B" to the 'On' (position 'I'). See 6.2 for introduction of a power tool.
Original Language Version
fig.4
fig.6
DFS35M Issue 4 14/07/2020