esera automation 1-Wire Extension 5 User Manual

esera automation 1-Wire Extension 5 User Manual

5-fold distribution module for 1-wire temperature sensors

Advertisement

Quick Links

Art.No. 11108

Features

Distributor for 1-Wire Temperature sensors with
RJ12 connectors
5 outputs for temperature sensors
Housing for wall mounting
Connection via screw plug connector
Improvement of the signal quality through
additional electronics

Typical areas of application

Temperature monitoring of heat storage tanks
Heating control, building management system and
air conditioning
Monitoring of frozen goods
Quality assurance
laboratory equipment, scientific devices
Industrial temperature measurement
1

Introduction

Before you start to install the 1-Wire Extension 5 and put the device into operation, please read this manual
carefully until the end, especially the section of the safety instructions.
2

Product Description

The 1-Wire Extension 5 is designed as local distributor for 1-Wire temperature sensors with RJ12 connector.
In combination with the different cable lengths of the temperature sensors a simple and fast cabling of up to
5 temperature sensors is possible, e.g. in the area of a heating system or industrial plant.
The design of the outputs with RJ12 sockets eliminates errors compared to distributors with clamp
connections or "luster terminals".
The cable temperature sensors and the 1-Wire Extension 5 form a coordinated cabling system.
As further system components for the 1-Wire network, we recommend the use of a
supply,
1-Wire bus coupler
No software is required for this module.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
User Guide
5-fold distribution module for
1-Wire Temperature Sensors
1-Wire Extension 5
1
1
or
-Wire Controller
as coupling to the control computer.
11108 V1.0 R1.0 Manual
Illustration similar ,module without LED displays
1-Wire Hub II
as power
Page 1 of 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1-Wire Extension 5 and is the answer not in the manual?

Questions and answers

Summary of Contents for esera automation 1-Wire Extension 5

  • Page 1 Industrial temperature measurement Illustration similar ,module without LED displays Introduction Before you start to install the 1-Wire Extension 5 and put the device into operation, please read this manual carefully until the end, especially the section of the safety instructions. Product Description The 1-Wire Extension 5 is designed as local distributor for 1-Wire temperature sensors with RJ12 connector.
  • Page 2 The distribution module has 5 outputs with RJ12 sockets. Here 1-Wire cable temperature sensors can be connected directly. It is not necessary to remove the plugs, because the plugs of the temperature sensors are connected to the 1-Wire Extension 5 are coordinated. The output sockets (RJ12 Western socket) are assigned as follows Assignment RJ12 socket:...
  • Page 3 Art.No. 11108 1-Wire Network For short connection lengths, no special requirements are placed on the cable used. With unshielded cable, a longer connection length can be achieved in an undisturbed environment, since the capacitive bus load is lower. A total length of 60 m should be achievable without additional measures. In a disturbed environment, the cable should be shielded (e.g.
  • Page 4  If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed upstream or a suitable power supply can be used.  After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance, https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance) must be carried out.