S&T kontron FlatClient ECO User Manual

S&T kontron FlatClient ECO User Manual

Hide thumbs Also See for kontron FlatClient ECO:
Table of Contents

Advertisement

Quick Links

USER GUIDE
FlatClient ECO and FlatClient PRO,
FlatClient RCK and FlatClient STS
User Guide Rev. 1.98
Doc. ID: 1061-6259
www.kontron.com
// 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the kontron FlatClient ECO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for S&T kontron FlatClient ECO

  • Page 1  USER GUIDE FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS User Guide Rev. 1.98 Doc. ID: 1061-6259 www.kontron.com // 1...
  • Page 2 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 This page has been intentionally left blank www.kontron.com // 2...
  • Page 3 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 FLATCLIENT ECO AND FLATCLIENT PRO, FLATCLIENT RCK  AND FLATCLIENT STS – USER GUIDE Disclaimer Kontron would like to point out that the information contained in this user guide may be subject to alteration, particularly as a result of the constant upgrading of Kontron products.
  • Page 4 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Intended Use THIS DEVICE AND ASSOCIATED SOFTWARE ARE NOT DESIGNED, MANUFACTURED OR INTENDED FOR USE OR RESALE FOR THE OPERATION OF NUCLEAR FACILITIES, THE NAVIGATION, CONTROL OR COMMUNICATION SYSTEMS FOR AIRCRAFT OR OTHER TRANSPORTATION, AIR TRAFFIC CONTROL, LIFE SUPPORT OR LIFE SUSTAINING APPLICATIONS, WEAPONS SYSTEMS, OR ANY OTHER APPLICATION IN A HAZARDOUS ENVIRONMENT, OR REQUIRING FAIL-SAFE PERFORMANCE, OR IN WHICH THE FAILURE OF...
  • Page 5 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Revision History Revision Brief Description of Changes Date of Issue Author Initial Issue 2017-July-12 Added Skylake and Kaby Lake variants 2018-June-29 Changed the 15” built-in mechanical diagrams 2018-Oct-02 Added 10.1", 12.2"...
  • Page 6 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Customer Service As a trusted technology innovator and global solutions provider, Kontron extends its embedded market strengths into a services portfolio allowing companies to break the barriers of traditional product lifecycles. Proven product expertise coupled with collaborative and highly-experienced support enables Kontron to provide exceptional peace of mind to build and maintain successful products.
  • Page 7: Symbols

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Symbols The following symbols may be used in this user guide DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 8: For Your Safety

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 For Your Safety Your new Kontron product was developed and tested carefully to provide all features necessary to ensure its compliance with electrical safety requirements. It was also designed for a long fault-free life. However, the life expectancy of your product can be drastically reduced by improper treatment during unpacking and installation.
  • Page 9: Lithium Battery Precautions

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Lithium Battery Precautions If your product is equipped with a lithium battery, take the following precautions when replacing the battery. Danger of explosion if the battery is replaced incorrectly. ...
  • Page 10: Table Of Contents

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Table of Contents Symbols............................................7 For Your Safety ......................................... 8 High Voltage Safety Instructions ..................................8 Special Handling and Unpacking Instruction ..............................8 Lithium Battery Precautions ....................................9 General Instructions on Usage ....................................
  • Page 11 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.13.1. 15.0" Panel Cutout ..................................... 45 7.14. 15.0“ Full-metal Variant .................................... 46 7.15. 15.6“ Built-in Variant ....................................47 7.15.1. 15.6" Panel Cutout ..................................... 47 7.16. 15.6“ Built-in Slim Variant ..................................48 7.17.
  • Page 12: List Of Tables

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.4. FlatClient PRO Haswell ....................................74 8.4.1. Input Power Connector .................................... 74 8.4.2. Power-Switch and LEDs ..................................75 8.4.3. USB3.0 Type-A Connector ..................................75 8.4.4. GbE RJ-45 Connector ....................................76 8.4.5.
  • Page 13: List Of Figures

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Table 25: Pinout VGA Connector ..................................67 Table 26: Pinout RS-232/422/485 Connector ............................68 Table 27: Power LED (1) ....................................... 69 Table 28: Button Functions (2) ..................................70 Table 29: Drive Activity (3) ....................................
  • Page 14: 1/ Introduction

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 1/ Introduction With its FlatClient Monitor series, Kontron offers high mechanical flexibility with respect to the design. It can be used both as a full-metal solution with VESA 75/75 respectively 100/100 as well as a built-in solution. The front comes with standard IP65 protection, with the full-metal variant offering a standard IP54.
  • Page 15: 2/ General Safety Instructions For Electronic Devices

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 2/ General Safety Instructions for Electronic Devices Please read this passage carefully and take careful note of the instructions, which have been compiled for your safety and to ensure to apply in accordance with intended regulations.
  • Page 16: Ul Canada: Instructions Générales De Sécurité Pour Les Appareils Électroniques

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98  a reliable protective earthing connection is provided  a suitable, easily accessible disconnecting device is used in the application (e.g. overcurrent protective device), if the device itself is not disconnect able ...
  • Page 17: Instructions De Sécurité Supplémentaires Pour Les Circuits D'alimentation En Courant Continu (Non E/S1/Selv)17

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98  La manipulation et le fonctionnement du produit ne sont autorisés que pour le personnel formé dans un lieu de travail dont l'accès est contrôlé. ...
  • Page 18: Electrostatic Discharge (Esd)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 2.5. Electrostatic Discharge (ESD) A sudden discharge of electrostatic electricity can destroy static-sensitive devices or micro-circuitry. Therefore, proper packaging and grounding techniques are necessary precautions to prevent damage. Always take the following precautions: ESD Sensitive Device! Keep electrostatic sensitive parts in their containers until they arrive at the ESD-safe...
  • Page 19: 3/ Scope Of Delivery

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 3/ Scope of Delivery This chapter describes the components that are delivered and can be optionally ordered. Please check that your delivery is complete and contains the items below (according to the ordered unit configuration).
  • Page 20 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Part Number Part Description PR22-100007-01 Adapter VGA - DisplayPort 1.1, Delock: 65567 PR22-100008-01 Adapter DVI-I – HDMI, Delock: 65467 840-0758 DisplayPort cable 1,8m 840-0759 DisplayPort cable 3m 840-0760 DisplayPort cable 5m 840-0598...
  • Page 21: Type Label And Product Identification

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 3.1.1. Type Label and Product Identification Product and Package Label, size 85 x 35mm, polyester matt silver. Certification print Figure 2: Type Label Short Description Barcode Part-Number Barcode Series# Technical data...
  • Page 22: 4/ Order Information

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 4/ Order Information E N 0 0 - y y y y y y - x x EN00- 4GB RAM/32GB M.2 4GB RAM/64GB M.2 4GB RAM/128GB M.2 4GB RAM/256GB M.2 4GB RAM/512GB M.2 8GB RAM/32GB M.2...
  • Page 23 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 EN00- with Protection glass and stainless steel front (STS) with Touch resistiv and stainless steel front (STS) with Touch PCAP and stainless steel front (STS) with Touch PCAP V2 with Protection glass V2 Slim with PCAP (V2)
  • Page 24 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 EN00- Projects 65.0" APL4 Apollolake N4200 only Projects 65.0" SLU2 Skylake i5-6300U only 10.1" APL4 Apollolake N4200 10.1" SLU2 Skylake i5-6300U 12.1"WXGA APL4 Apollolake N4200 12.1"WXGA SLU2 Skylake i5-6300U 13.3"...
  • Page 25: 5/ Product Description

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 5/ Product Description 5.1. Product View Figure 3: Front View Description FlatClient ECO Full-metal RFID sign (option) TFT Display with resistive touch Front plate www.kontron.com // 25...
  • Page 26: Figure 4: Bottom View Description - Flatclient Eco (Baytrail) Full-Metal Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Figure 4: Bottom View Description – FlatClient ECO (BayTrail) Full-metal variant VGA connector USB 2.0 2x HDMI port VESA Mounting holes LAN interface 2x Power connector USB 3.0 Figure 5: Bottom View Description –...
  • Page 27: 6/ Technical Data And Environmental Specification

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 6/ Technical Data and Environmental Specification Table 4: Technical Data FlatClient ECO and FlatClient PRO Line Display Size 7.0" 10.1“ 10.4“ 12.1“ SVGA 12.1“ XGA Resolution (pixel) 800x480 1280x800...
  • Page 28: Table 6: Technical Data Flatclient Eco And Flatclient Pro Line

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Table 6: Technical Data FlatClient ECO and FlatClient PRO Line Display Size 15.6“ Full HD 17.0“ 18.5“ HD 18.5“ Full HD Slim Resolution 1920x1080, Full 1280x1024 1366x768, HD 1920x1080, Full...
  • Page 29: Table 8: Technical Data For Flatclient Eco Line With Baytrail And Braswell Processors

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Table 8: Technical Data for FlatClient ECO Line with BayTrail and Braswell processors Intel® BayTrail Celeron Quad Core Option: Intel® Braswell Celeron J1900 Quad Core N3150(DT) Memory 4GB DDR3 SO-DIMM BIOS...
  • Page 30: Table 10: Technical Data Flatclient Eco Line With Intel® Pentium® Cpu N4200

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Table 10: Technical Data FlatClient ECO Line with Intel® Pentium® CPU N4200 Intel® Pentium® CPU N4200 Memory 4 GB DDR3L BIOS AMI uEFI BIOS Hardware Monitor Temperature, Voltages Watchdog Programmable WDT to generate System reset event...
  • Page 31: Table 12: Technical Data Flatclient Pro Line With Haswell And Broadwell Processors

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Table 12: Technical Data FlatClient PRO Line with Haswell and Broadwell processors Intel® Haswell ULT i5-4300U Option: Intel® Broadwell ULT i5- 5350U Memory 4 GB DDR3 SO-DIMM BIOS AMI uEFI BIOS Hardware Monitor...
  • Page 32: Table 14: Technical Data Flatclient Pro Line With Skylake And Kaby Lake Cpu

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Table 14: Technical Data FlatClient PRO Line with Skylake and Kaby Lake CPU Intel® Skylake ULT Core™ i5- Intel® Kaby Lake ULT Core™ i5- 6300U 7300U Memory 4 GB DDR4 SO-DIMM...
  • Page 33: Table 16: Environmental Specification Flatclient Eco And Flatclient Pro Line

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Table 16: Environmental Specification FlatClient ECO and FlatClient PRO Line Operating Altitude Up to 3000 m (9900 ft) Storage Altitude Up to 5000 m (16500 ft) Humidity 10%-90% @ 39°C, non condensing Certification...
  • Page 34: 7/ Mechanical Specification

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7/ Mechanical specification 7.1. 7.0“ Built-in Variant 7.2. 7.0"Panel Cutout www.kontron.com // 34...
  • Page 35: Built-In Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.3. 10.1“ Built-in Variant 7.3.1. 10.1"Panel Cutout www.kontron.com // 35...
  • Page 36: Full-Metal Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.4. 10.1“ Full-metal Variant www.kontron.com // 36...
  • Page 37: Built-In Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.5. 10.4“ Built-in Variant 7.5.1. 10.4" Panel Cutout www.kontron.com // 37...
  • Page 38: Full-Metal Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.6. 10.4“ Full-metal Variant www.kontron.com // 38...
  • Page 39: Built-In Variant Wxga (1280X800)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.7. 12.1“ Built-in Variant WXGA (1280x800) 7.7.1. 12.1" WXGA Panel Cutout www.kontron.com // 39...
  • Page 40: Full-Metal Variant Wxga (1280X800)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.8. 12.1“ Full-metal Variant WXGA (1280x800) www.kontron.com // 40...
  • Page 41: Built-In Variant Svga And Xga (800X600, 1024X768)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.9. 12.1“ Built-in Variant SVGA and XGA (800x600, 1024x768) 7.9.1. 12.1" Panel Cutout www.kontron.com // 41...
  • Page 42: Full-Metal Variant Svga And Xga (800X600, 1024X768)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.10. 12.1“ Full-metal Variant SVGA and XGA (800x600, 1024x768) www.kontron.com // 42...
  • Page 43: Built-In Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.11. 13.3“ Built-in Variant 7.11.1. 13.3" Panel Cutout www.kontron.com // 43...
  • Page 44: Full-Metal Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.12. 13.3“ Full-metal Variant www.kontron.com // 44...
  • Page 45: Built-In Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.13. 15.0“ Built-in Variant 12.2 [0.48]“ 7.13.1. 15.0" Panel Cutout www.kontron.com // 45...
  • Page 46: Full-Metal Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.14. 15.0“ Full-metal Variant www.kontron.com // 46...
  • Page 47: Built-In Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.15. 15.6“ Built-in Variant 7.15.1. 15.6" Panel Cutout www.kontron.com // 47...
  • Page 48: Built-In Slim Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.16. 15.6“ Built-in Slim Variant 7.17. 15.6“ Full-metal Variant www.kontron.com // 48...
  • Page 49: Vesa Slim Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.18. 15.6“ VESA Slim Variant www.kontron.com // 49...
  • Page 50: Built-In Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.19. 17.0“ Built-in Variant 7.19.1. 17.0" Panel Cutout www.kontron.com // 50...
  • Page 51: Full-Metal Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.20. 17.0“ Full-metal Variant www.kontron.com // 51...
  • Page 52: Built-In Variant (Hd And Fullhd)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.21. 18.5“ Built-in Variant (HD and FullHD) 7.21.1. 18.5" Panel Cutout www.kontron.com // 52...
  • Page 53: Built-In Slim Variant (Hd And Fullhd)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.22. 18.5“ Built-in Slim Variant (HD and FullHD) 7.23. 18.5“ Full-metal Variant (HD and FullHD) www.kontron.com // 53...
  • Page 54: Vesa Slim Variant (Hd And Fullhd)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.24. 18.5“ VESA Slim Variant (HD and FullHD) www.kontron.com // 54...
  • Page 55: Built-In Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.25. 19.0“ Built-in Variant 7.25.1. 19.0" Panel Cutout www.kontron.com // 55...
  • Page 56: Full-Metal Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.26. 19.0“ Full-metal Variant www.kontron.com // 56...
  • Page 57: 19" Monitor Rackmount (Rck)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.27. 19” Monitor Rackmount (RCK) www.kontron.com // 57...
  • Page 58: Built-In Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.28. 21.5“ Built-in Variant 7.28.1. 21.5" Panel Cutout www.kontron.com // 58...
  • Page 59: Built-In Slim Variant (Hd And Fullhd)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.29. 21.5“ Built-in Slim Variant (HD and FullHD) 7.30. 21.5“ Full-metal Variant www.kontron.com // 59...
  • Page 60: Vesa Slim Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.31. 21.5“ VESA Slim Variant www.kontron.com // 60...
  • Page 61: Built-In Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.32. 23.8“ Built-in Variant 7.32.1. 23.8 "Panel Cutout www.kontron.com // 61...
  • Page 62: Full-Metal Variant

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 7.33. 23.8“ Full-metal Variant www.kontron.com // 62...
  • Page 63: 8/ Connectors

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8/ Connectors 8.1. FlatClient ECO Intel BayTrail J1900 Figure 6: Interfaces for Panel PC FlatClient ECO Earth stud USB 3.0 VGA connector 2x USB 2.0 HDMI Power/LEDs 2x GbE...
  • Page 64: Input Power Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.2.1. Input Power Connector Figure 8: Input Power Shield Figure 9: Mating Connector Manufacturer: Phoenix Contact Product: PSC 1,5/ 3-F Order#: 1841909 www.kontron.com // 64...
  • Page 65: Power-Switch And Leds

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.2.2. Power-Switch and LEDs Figure 10: Power-Switch and LEDs Power on LED Power LED Drive Activity Table 18: Button Functions (1) Button Functions Activity Pressed during active system OS is put into sleep state Pressed when power LED is OS is started from sleep state...
  • Page 66: Gbe Rj-45 Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Table 22: Pinout USB 2.0 Signal Name Signal Name +USB_VCC USB_RX- USB_D- USB_RX+ USB_D+ USB_TX- USB_TX+ 8.2.5. GbE RJ-45 Connector Table 23: Pinout GbE RJ-45 Connector Signal Name Signal Name TX1+...
  • Page 67: Hdmi Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.2.7. HDMI Connector Table 24: Pinout HDMI Connector Signal Name TMDS Data2+ TMDS Data2– TMDS Data1+ TMDS Data1– TMDS Data0+ TMDS Data0– TMDS Clock+ TMDS Clock– Reserved Reserved DDC_CLK...
  • Page 68: Com2 Rs-232/422/485 (Via Internal Cable Connection To Cn16, Option)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.2.9. COM2 RS-232/422/485 (via internal cable connection to CN16, Option) Table 26: Pinout RS-232/422/485 Connector Half Duplex Full Dup- RS-232 RS-422 RS-485 lex RS-485 DATA- DATA+ 8.3.
  • Page 69: Input Power Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.3.1. Input Power Connector Figure 12: Input Power Shield Figure 13: Mating Connector Manufacturer: Phoenix Contact Product: PSC 1,5/ 3-F Order#: 1841909 8.3.2. Power-Switch and LEDs Figure 14: Power-Switch and LEDs LED Power Power on...
  • Page 70: Usb2.0 Type-A Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Table 28: Button Functions (2) Button Functions Activity Pressed during active system OS is put into sleep state Pressed when power LED is OS is started from sleep state green-blinking Pressed when system was New OS start...
  • Page 71: Usb3.0 Type-A Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.3.4. USB3.0 Type-A Connector Table 31: Pinout USB 2.0 Signal Name Signal Name +USB_VCC USB_RX- USB_D- USB_RX+ USB_D+ USB_TX- USB_TX+ 8.3.5. GbE RJ-45 Connector Table 32: Pinout GbE RJ-45 Connector Signal Name Signal Name TX1+...
  • Page 72: Hdmi Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.3.7. HDMI Connector Table 34: Pinout HDMI Connector Signal Name TMDS Data2+ TMDS Data2– TMDS Data1+ TMDS Data1– TMDS Data0+ TMDS Data0– TMDS Clock+ TMDS Clock– Reserved Reserved DDC_CLK...
  • Page 73: Db15 Vga Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.3.8. DB15 VGA Connector Table 35: Pinout VGA Connector Signal Name Signal Name Green Blue n.c. n.c. DDC Data Hsync Vsync DDC Clock 8.3.9. COM2 RS-232/422/485 (via internal cable connection to CN16, Option) Table 36: Pinout RS-232/422/485 Connector Half Duplex Full Dup-...
  • Page 74: Flatclient Pro Haswell

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.4. FlatClient PRO Haswell Figure 15: Interfaces for Panel PC PRO variant LAN interface 3x Earth stud DisplayPort 2x Power connector USB 3.0 4x Power/LEDs 8.4.1.
  • Page 75: Power-Switch And Leds

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.4.2. Power-Switch and LEDs Figure 18: Power-Switch and LEDs Power on LED Power LED Drive Activity Table 37: Power On Button Functions (1) Button Functions Activity Pressed during active system OS is put into sleep state...
  • Page 76: Gbe Rj-45 Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.4.4. GbE RJ-45 Connector Table 41: Pinout GbE RJ-45 Connector Signal Name Signal Name TX1+ TX3- TX1- TX2- TX2+ TX4+ TX3+ TX4- 8.4.5. LED Diagram of LAN Connectors Table 8: Status of LEDs from GbE RJ-45 Connector left LED: activity/link right LED: 10/100/1000...
  • Page 77: Com2 Rs-232/422/485 (Via Internal Cable Connection To Cn16, Option)

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.4.7. COM2 RS-232/422/485 (via internal cable connection to CN16, Option) Table 43: Pinout RS-232/422/485 Connector Half Duplex Full Dup- RS-232 RS-422 RS-485 lex RS-485 DATA- DATA+ www.kontron.com // 77...
  • Page 78: Flatclient Pro Skylake/Kaby Lake

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.5. Flatclient PRO Skylake/Kaby Lake Figure 19: Interfaces for Panel PC FlatClient PRO Skylake/Kaby Lake variant HDMI Earth stud DP connector Power connector 2x GbE 4x USB 3.0 Power/LEDs 8.5.1.
  • Page 79: Power-Switch And Leds

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.5.2. Power-Switch and LEDs Figure 22: Power-Switch and LEDs Power LED Power On LED Drive Activity Table 44: Power LED (1) Signal No Power Green Active Green blinking Standby...
  • Page 80: Gbe Rj-45 Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.5.4. GbE RJ-45 Connector Table 48: Pinout GbE RJ-45 Connector Signal Name Signal Name TX1+ TX3- TX1- TX2- TX2+ TX4+ TX3+ TX4- 8.5.5. LED Diagram of LAN Connectors Table 8: Status of LEDs from GbE RJ-45 Connector left LED: activity/link right LED: 10/100/1000...
  • Page 81: Hdmi Connector

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 8.5.7. HDMI Connector Table 50: Pinout HDMI Connector Signal Name TMDS Data2+ TMDS Data2– TMDS Data1+ TMDS Data1– TMDS Data0+ TMDS Data0– TMDS Clock+ TMDS Clock– Reserved Reserved DDC_CLK...
  • Page 82: 9/ Installation And Start

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 9/ Installation and Start 9.1. Mounting Instructions (built-in-variant only) Fixation screw torque is 0,8 Nm +/- 0,2 Nm. Step Installation Description  Use mounting set with screws and clamping brackets ...
  • Page 83 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Step Installation Description  Fix the bracket with the screw to the housing  Repeat step 4 for all positions of clamping bracket Wall-/Switch cabinet doors thickness has to be at least 3 mm. Otherwise use an adapter frame or adapter brackets.
  • Page 84: Startup Procedure

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 9.2. Startup Procedure To activate your FlatClient Panel PC connect the power supply to power connector on the FlatClient back side. Alternative use the mating power connector for connecting your power cable. The LED “PWR” gives a green or blue light now.
  • Page 85: 10/ Technical Support

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Technical Support For technical support contact our Support Department:  E-mail: support@kontron.com  Phone: +49-821-4086-888 Make sure you have the following information available when you call: ...
  • Page 86 FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Fax: +49 (0) 821 4086 111 Email: service@kontron.com The goods for repair must be packed properly for shipping, considering shock and ESD protection. Goods returned to Kontron Europe GmbH in non-proper packaging will be considered as customer caused faults and cannot be accepted as warranty repairs.
  • Page 87: Appendix A: List Of Acronyms

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 Appendix A: List of Acronyms Application Programming Interface Base Management Controller Command-Line Interface Computer-on-Module Error Checking and Correction Field Replaceable Unit Graphics Processing Unit HD/HDD Hard Disk /Drive PICMG Hardware Platform Management specification family...
  • Page 88: About Kontron

    FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.98 About Kontron – Member of the S&T Group Kontron is a global leader in Embedded Computing Technology (ECT). As a part of technology group S&T, Kontron offers a combined portfolio of secure hardware, middleware and services for Internet of Things (IoT) and Industry 4.0 applications.

Table of Contents