Table of Contents

Advertisement

Quick Links

USER GUIDE
FlatClient ECO and FlatClient PRO
Doc. Rev. 1.95
Doc. ID: 1061-6259
www.kontron.com
// 1

Advertisement

Table of Contents
loading

Summary of Contents for S&T kontron FlatClient Series

  • Page 1  USER GUIDE FlatClient ECO and FlatClient PRO Doc. Rev. 1.95 Doc. ID: 1061-6259 www.kontron.com // 1...
  • Page 2 FlatClient ECO and FlatClient PRO – Rev. 1.95 This page has been intentionally left blank www.kontron.com // 2...
  • Page 3 FlatClient ECO and FlatClient PRO – Rev. 1.95  FLATCLIENT ECO AND FLATCLIENT PRO – USER GUIDE Disclaimer Kontron would like to point out that the information contained in this user guide may be subject to alteration, particularly as a result of the constant upgrading of Kontron products. This document does not entail any guarantee on the part of Kontron with respect to technical processes described in the user guide or any product characteristics set out in the user guide.
  • Page 4 FlatClient ECO and FlatClient PRO – Rev. 1.95 Intended Use THIS DEVICE AND ASSOCIATED SOFTWARE ARE NOT DESIGNED, MANUFACTURED OR INTENDED FOR USE OR RESALE FOR THE OPERATION OF NUCLEAR FACILITIES, THE NAVIGATION, CONTROL OR COMMUNICATION SYSTEMS FOR AIRCRAFT OR OTHER TRANSPORTATION, AIR TRAFFIC CONTROL, LIFE SUPPORT OR LIFE SUSTAINING APPLICATIONS, WEAPONS SYSTEMS, OR ANY OTHER APPLICATION IN A HAZARDOUS ENVIRONMENT, OR REQUIRING FAIL-SAFE PERFORMANCE, OR IN WHICH THE FAILURE OF PRODUCTS COULD LEAD DIRECTLY TO DEATH, PERSONAL INJURY, OR SEVERE PHYSICAL OR...
  • Page 5 FlatClient ECO and FlatClient PRO – Rev. 1.95 Revision History Revision Brief Description of Changes Date of Issue Author Initial Issue 2017-July-12 Added Skylake and Kaby Lake variants 2018-June-29 Changed the 15” built-in mechanical diagrams 2018-Oct-02 Added 10.1", 12.2" and 13.3" chapter, added Apollo Lake 2019-Mar-21 variants, changed Power-in to 12-30VDC, Added French safety instructions...
  • Page 6: Symbols

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Symbols The following symbols may be used in this user guide DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 7: For Your Safety

    FlatClient ECO and FlatClient PRO – Rev. 1.95 For Your Safety Your new Kontron product was developed and tested carefully to provide all features necessary to ensure its compliance with electrical safety requirements. It was also designed for a long fault-free life. However, the life expectancy of your product can be drastically reduced by improper treatment during unpacking and installation.
  • Page 8: Lithium Battery Precautions

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Lithium Battery Precautions If your product is equipped with a lithium battery, take the following precautions when replacing the battery. Danger of explosion if the battery is replaced incorrectly.  Replace only with same or equivalent battery type recommended by the manufacturer. ...
  • Page 9: Table Of Contents

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Table of Contents Symbols ..........................................6 For Your Safety ........................................7 High Voltage Safety Instructions .................................. 7 Special Handling and Unpacking Instruction ............................7 Lithium Battery Precautions ..................................8 General Instructions on Usage..................................8 Quality and Environmental Management ..............................
  • Page 10 FlatClient ECO and FlatClient PRO – Rev. 1.95 7.13. 15.0“ Built-in Variant ..................................... 43 7.13.1. 15.0" Panel Cutout ....................................43 7.14. 15.0“ Full-metal Variant ..................................44 7.15. 15.6“ Built-in Variant ....................................45 7.15.1. 15.6" Panel Cutout ....................................45 7.16. 15.6“ Built-in Slim Variant ..................................46 7.17.
  • Page 11: List Of Tables

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.4. FlatClient PRO Haswell................................... 71 8.4.1. Input Power Connector ..................................71 8.4.2. Power-Switch and LEDs ..................................72 8.4.3. USB3.0 Type-A Connector ................................72 8.4.4. GbE RJ-45 Connector ..................................73 8.4.5. LED Diagram of LAN Connectors ..............................73 8.4.6.
  • Page 12: List Of Figures

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Table 26: Pinout RS-232/422/485 Connector ............................65 Table 27: Power LED (1) ....................................66 Table 28: Button Functions (2) ................................... 67 Table 29: Drive Activity (3) ................................... 67 Table 30: Pinout USB 2.0 ....................................67 Table 31: Pinout USB 2.0 ....................................
  • Page 13: 1/ Introduction

    FlatClient ECO and FlatClient PRO – Rev. 1.95 1/ Introduction With its FlatClient Monitor series, Kontron offers high mechanical flexibility with respect to the design. It can be used both as a full-metal solution with VESA 75/75 respectively 100/100 as well as a built-in solution. The front comes with standard IP65 protection, with the full-metal variant offering a standard IP54.
  • Page 14: 2/ General Safety Instructions For Electronic Devices

    FlatClient ECO and FlatClient PRO – Rev. 1.95 2/ General Safety Instructions for Electronic Devices Please read this passage carefully and take careful note of the instructions, which have been compiled for your safety and to ensure to apply in accordance with intended regulations. If the following general safety instructions are not observed, it could lead to injuries to the operator and/or damage of the product;...
  • Page 15: Ul Canada: Instructions Générales De Sécurité Pour Les Appareils Électroniques

    FlatClient ECO and FlatClient PRO – Rev. 1.95  a disconnect device, if provided in or as part of the equipment, shall disconnect both poles simultaneously  interconnecting power circuits of different devices cause no electrical hazards  A sufficient dimensioning of the power cable wires must be selected – according to the maximum electrical specifications on the product label –...
  • Page 16: Instructions De Sécurité Supplémentaires Pour Les Circuits D'alimentation En Courant Continu (Non E/S1/Selv)16

    FlatClient ECO and FlatClient PRO – Rev. 1.95  ATTENTION : Risque d'explosion si la batterie est remplacée de manière incorrecte (court-circuit, inversion de polarité, mauvais type de batterie). Éliminez les piles usagées conformément aux instructions du fabricant. 2.2.1. Instructions de sécurité supplémentaires pour les circuits d'alimentation en courant continu (non E/S1/SELV) ...
  • Page 17: Grounding Methods

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Always take the following precautions: ESD Sensitive Device! Keep electrostatic sensitive parts in their containers until they arrive at the ESD-safe workplace. Always be properly grounded when touching a sensitive board, component, or assembly.
  • Page 18: 3/ Scope Of Delivery

    FlatClient ECO and FlatClient PRO – Rev. 1.95 3/ Scope of Delivery This chapter describes the components that are delivered and can be optionally ordered. Please check that your delivery is complete and contains the items below (according to the ordered unit configuration).
  • Page 19 FlatClient ECO and FlatClient PRO – Rev. 1.95 Part Number Part Description PR22-100007-01 Adapter VGA - DisplayPort 1.1, Delock: 65567 PR22-100008-01 Adapter DVI-I – HDMI, Delock: 65467 840-0758 DisplayPort cable 1,8m 840-0759 DisplayPort cable 3m 840-0760 DisplayPort cable 5m 840-0598 Adapter VGA/DVI 840-0039 VGA/SVGA cable 1,8m/2,0m...
  • Page 20: Type Label And Product Identification

    FlatClient ECO and FlatClient PRO – Rev. 1.95 3.1.1. Type Label and Product Identification Product and Package Label, size 85 x 35mm, polyester matt silver. Certification print Figure 2: Type Label Short Description Barcode Part-Number Barcode Series# Technical data internal use www.kontron.com // 20...
  • Page 21: 4/ Order Information

    FlatClient ECO and FlatClient PRO – Rev. 1.95 4/ Order Information E N 0 0 - y y y y y y - x x EN00- 4GB RAM/32GB M.2 4GB RAM/64GB M.2 4GB RAM/128GB M.2 4GB RAM/256GB M.2 4GB RAM/512GB M.2 8GB RAM/32GB M.2 8GB RAM/64GB M.2 8GB RAM/128GB M.2...
  • Page 22 FlatClient ECO and FlatClient PRO – Rev. 1.95 Slim with PCAP (V2) and stainless steel front Slim with Protection glass (V2) and stainless steel front 10.4" 12.1" 15.0" 15.6" 17.0" 18.5" 19.0" 21.5" 15.6" 17.0" 18.5" 19.0" 21.5" 15.0" 12.1" 10.4"...
  • Page 23: 5/ Product Description

    FlatClient ECO and FlatClient PRO – Rev. 1.95 5/ Product Description 5.1. Product View Figure 3: Front View Description FlatClient ECO Full-metal RFID sign (option) TFT Display with resistive touch Front plate www.kontron.com // 23...
  • Page 24: Figure 4: Bottom View Description - Flatclient Eco (Baytrail) Full-Metal Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Figure 4: Bottom View Description – FlatClient ECO (BayTrail) Full-metal variant VGA connector USB 2.0 2x HDMI port VESA Mounting holes LAN interface 2x Power connector USB 3.0 Figure 5: Bottom View Description – FlatClient PRO (Braswell) built-in variant variant LAN ports 3x Power connector DisplayPort 2x...
  • Page 25: 6/ Technical Data And Environmental Specification

    FlatClient ECO and FlatClient PRO – Rev. 1.95 6/ Technical Data and Environmental Specification Table 4: Technical Data FlatClient ECO and FlatClient PRO Line Display Size 7.0" 10.1“ 10.4“ 12.1“ SVGA 12.1“ XGA Resolution (pixel) 800x480 1280x800 800x600, SVGA 800x600, SVGA 1024x768, XGA 0,672916667 16:10...
  • Page 26: Table 6: Technical Data Flatclient Eco And Flatclient Pro Line

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Table 6: Technical Data FlatClient ECO and FlatClient PRO Line Display Size 15.6“ Full HD 17.0“ 18.5“ HD 18.5“ FullHD Slim Resolution 1920x1080, Full 1280x1024 1366x768, HD 1920x1080, FullHD Format 16:9 16:9 16:9 Contrast Ratio 500:1...
  • Page 27: Table 8: Technical Data For Flatclient Eco Line With Baytrail And Braswell Processors

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Table 8: Technical Data for FlatClient ECO Line with BayTrail and Braswell processors Intel® BayTrail Celeron Quad Core Option: Intel® Braswell Celeron J1900 Quad Core N3150(DT) Memory 4GB DDR3 SO-DIMM AMI uEFI BIOS BIOS I/O Standard 2xGbE (1x Intel®...
  • Page 28: Table 10: Technical Data Flatclient Eco Line With Intel® Pentium® Cpu N4200

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Table 10: Technical Data FlatClient ECO Line with Intel® Pentium® CPU N4200 Intel® Pentium® CPU N4200 Memory 4 GB DDR3L BIOS AMI uEFI BIOS Hardware Monitor Temperature, Voltages Watchdog Programmable WDT to generate System reset event Realtime Clock (RTC) Processor integrated RTC 2xGbE (RJ-45 on rear, Intel®...
  • Page 29: Table 12: Technical Data Flatclient Pro Line With Haswell And Broadwell Processors

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Table 12: Technical Data FlatClient PRO Line with Haswell and Broadwell processors Intel® Haswell ULT i5-4300U Option: Intel® Broadwell ULT i5- 5350U Memory 4 GB DDR3 SO-DIMM AMI uEFI BIOS BIOS Hardware Monitor Temperature, Voltages Watchdog Programmable WDT to generate System reset event...
  • Page 30: Table 14: Technical Data Flatclient Pro Line With Skylake And Kaby Lake Cpu

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Table 14: Technical Data FlatClient PRO Line with Skylake and Kaby Lake CPU Intel® Skylake ULT Core™ i5- Intel® Kaby Lake ULT Core™ i5- 6300U 7300U Memory 4 GB DDR4 SO-DIMM AMI uEFI BIOS BIOS Hardware Monitor Temperature, Voltages...
  • Page 31: Table 16: Environmental Specification Flatclient Eco And Flatclient Pro Line

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Table 16: Environmental Specification FlatClient ECO and FlatClient PRO Line Operating Altitude Up to 3000 m (9900 ft) Storage Altitude Up to 5000 m (16500 ft) Humidity 10%-90% @ 39°C, non condensing Certification CE, cULus (only for Haswell and BayTrail CPU) Protection Class...
  • Page 32: 7/ Mechanical Specification

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7/ Mechanical specification 7.1. 7.0“ Built-in Variant 7.2. 7.0"Panel Cutout www.kontron.com // 32...
  • Page 33: Built-In Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.3. 10.1“ Built-in Variant 7.3.1. 10.1"Panel Cutout www.kontron.com // 33...
  • Page 34: Full-Metal Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.4. 10.1“ Full-metal Variant www.kontron.com // 34...
  • Page 35: Built-In Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.5. 10.4“ Built-in Variant 7.5.1. 10.4" Panel Cutout www.kontron.com // 35...
  • Page 36: Full-Metal Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.6. 10.4“ Full-metal Variant www.kontron.com // 36...
  • Page 37: Built-In Variant Wxga (1280X800)

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.7. 12.1“ Built-in Variant WXGA (1280x800) 7.7.1. 12.1" WXGA Panel Cutout www.kontron.com // 37...
  • Page 38: Full-Metal Variant Wxga (1280X800)

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.8. 12.1“ Full-metal Variant WXGA (1280x800) www.kontron.com // 38...
  • Page 39: Built-In Variant Svga And Xga (800X600, 1024X768)

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.9. 12.1“ Built-in Variant SVGA and XGA (800x600, 1024x768) 7.9.1. 12.1" Panel Cutout www.kontron.com // 39...
  • Page 40: Full-Metal Variant Svga And Xga (800X600, 1024X768)

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.10. 12.1“ Full-metal Variant SVGA and XGA (800x600, 1024x768) www.kontron.com // 40...
  • Page 41: Built-In Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.11. 13.3“ Built-in Variant 7.11.1. 13.3" Panel Cutout www.kontron.com // 41...
  • Page 42: Full-Metal Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.12. 13.3“ Full-metal Variant www.kontron.com // 42...
  • Page 43: Built-In Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.13. 15.0“ Built-in Variant 12.2 [0.48]“ 7.13.1. 15.0" Panel Cutout www.kontron.com // 43...
  • Page 44: Full-Metal Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.14. 15.0“ Full-metal Variant www.kontron.com // 44...
  • Page 45: Built-In Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.15. 15.6“ Built-in Variant 7.15.1. 15.6" Panel Cutout www.kontron.com // 45...
  • Page 46: Built-In Slim Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.16. 15.6“ Built-in Slim Variant 7.17. 15.6“ Full-metal Variant www.kontron.com // 46...
  • Page 47: Vesa Slim Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.18. 15.6“ VESA Slim Variant www.kontron.com // 47...
  • Page 48: Built-In Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.19. 17.0“ Built-in Variant 7.19.1. 17.0" Panel Cutout www.kontron.com // 48...
  • Page 49: Full-Metal Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.20. 17.0“ Full-metal Variant www.kontron.com // 49...
  • Page 50: Built-In Variant (Hd And Fullhd)

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.21. 18.5“ Built-in Variant (HD and FullHD) 7.21.1. 18.5" Panel Cutout www.kontron.com // 50...
  • Page 51: Built-In Slim Variant (Hd And Fullhd)

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.22. 18.5“ Built-in Slim Variant (HD and FullHD) 7.23. 18.5“ Full-metal Variant (HD and FullHD) www.kontron.com // 51...
  • Page 52: Vesa Slim Variant (Hd And Fullhd)

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.24. 18.5“ VESA Slim Variant (HD and FullHD) www.kontron.com // 52...
  • Page 53: Built-In Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.25. 19.0“ Built-in Variant 7.25.1. 19.0" Panel Cutout www.kontron.com // 53...
  • Page 54: Full-Metal Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.26. 19.0“ Full-metal Variant www.kontron.com // 54...
  • Page 55: Built-In Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.27. 21.5“ Built-in Variant 7.27.1. 21.5" Panel Cutout www.kontron.com // 55...
  • Page 56: Built-In Slim Variant (Hd And Fullhd)

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.28. 21.5“ Built-in Slim Variant (HD and FullHD) 7.29. 21.5“ Full-metal Variant www.kontron.com // 56...
  • Page 57: Vesa Slim Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.30. 21.5“ VESA Slim Variant www.kontron.com // 57...
  • Page 58: Built-In Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.31. 23.8“ Built-in Variant 7.31.1. 23.8 "Panel Cutout www.kontron.com // 58...
  • Page 59: Full-Metal Variant

    FlatClient ECO and FlatClient PRO – Rev. 1.95 7.32. 23.8“ Full-metal Variant www.kontron.com // 59...
  • Page 60: 8/ Connectors

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8/ Connectors 8.1. FlatClient ECO Intel BayTrail J1900 Figure 6: Interfaces for Panel PC FlatClient ECO Earth stud USB 3.0 VGA connector 2x USB 2.0 HDMI Power/LEDs 2x GbE Power connector 8.2. FlatClient ECO Intel BayTrail J1900 7" Variant Figure 7: Interfaces for Panel PC FlatClient ECO 7"...
  • Page 61: Input Power Connector

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.2.1. Input Power Connector Figure 8: Input Power Shield Figure 9: Mating Connector Manufacturer: Phoenix Contact Product: PSC 1,5/ 3-F Order#: 1841909 www.kontron.com // 61...
  • Page 62: Power-Switch And Leds

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.2.2. Power-Switch and LEDs Figure 10: Power-Switch and LEDs Power on LED Power LED Drive Activity Table 18: Button Functions (1) Activity Button Functions Pressed during active system OS is put into sleep state Pressed when power LED is OS is started from sleep state green-blinking...
  • Page 63: Gbe Rj-45 Connector

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Table 22: Pinout USB 2.0 Signal Name Signal Name +USB_VCC USB_RX- USB_D- USB_RX+ USB_D+ USB_TX- USB_TX+ 8.2.5. GbE RJ-45 Connector Table 23: Pinout GbE RJ-45 Connector Signal Name Signal Name TX1+ TX3- TX1- TX2- TX2+...
  • Page 64: Hdmi Connector

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.2.7. HDMI Connector Table 24: Pinout HDMI Connector Signal Name TMDS Data2+ TMDS Data2– TMDS Data1+ TMDS Data1– TMDS Data0+ TMDS Data0– TMDS Clock+ TMDS Clock– Reserved Reserved DDC_CLK DDC_DATA +5 V Power Hot Plug Detect 8.2.8.
  • Page 65: Com2 Rs-232/422/485 (Via Internal Cable Connection To Cn16, Option)

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.2.9. COM2 RS-232/422/485 (via internal cable connection to CN16, Option) Table 26: Pinout RS-232/422/485 Connector Half Duplex Full Dup- RS-232 RS-422 RS-485 lex RS-485 DATA- DATA+ 8.3. FlatClient ECO Apollo Lake N4200 Figure 11: Interfaces for Panel PC FlatClient Apollo Lake variant HDMI Earth stud...
  • Page 66: Input Power Connector

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.3.1. Input Power Connector Figure 12: Input Power Shield Figure 13: Mating Connector Manufacturer: Phoenix Contact Product: PSC 1,5/ 3-F Order#: 1841909 8.3.2. Power-Switch and LEDs Figure 14: Power-Switch and LEDs LED Power Power on LED Drive Activity Table 27: Power LED (1)
  • Page 67: Usb2.0 Type-A Connector

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Table 28: Button Functions (2) Button Functions Activity Pressed during active system OS is put into sleep state Pressed when power LED is OS is started from sleep state green-blinking Pressed when system was New OS start shut-down Table 29: Drive Activity (3)
  • Page 68: Usb3.0 Type-A Connector

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.3.4. USB3.0 Type-A Connector Table 31: Pinout USB 2.0 Signal Name Signal Name +USB_VCC USB_RX- USB_D- USB_RX+ USB_D+ USB_TX- USB_TX+ 8.3.5. GbE RJ-45 Connector Table 32: Pinout GbE RJ-45 Connector Signal Name Signal Name TX1+ TX3-...
  • Page 69: Hdmi Connector

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.3.7. HDMI Connector Table 34: Pinout HDMI Connector Signal Name TMDS Data2+ TMDS Data2– TMDS Data1+ TMDS Data1– TMDS Data0+ TMDS Data0– TMDS Clock+ TMDS Clock– Reserved Reserved DDC_CLK DDC_DATA +5 V Power Hot Plug Detect www.kontron.com // 69...
  • Page 70: Db15 Vga Connector

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.3.8. DB15 VGA Connector Table 35: Pinout VGA Connector Signal Name Signal Name Green Blue n.c. n.c. DDC Data Hsync Vsync DDC Clock 8.3.9. COM2 RS-232/422/485 (via internal cable connection to CN16, Option) Table 36: Pinout RS-232/422/485 Connector Half Duplex Full Dup-...
  • Page 71: Flatclient Pro Haswell

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.4. FlatClient PRO Haswell Figure 15: Interfaces for Panel PC PRO variant LAN interface 3x Earth stud DisplayPort 2x Power connector USB 3.0 4x Power/LEDs 8.4.1. Input Power Connector Figure 16: Input Power Shield Figure 17: Mating Connector Manufacturer: Phoenix Contact...
  • Page 72: Power-Switch And Leds

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.4.2. Power-Switch and LEDs Figure 18: Power-Switch and LEDs Power on LED Power LED Drive Activity Table 37: Power On Button Functions (1) Button Functions Activity Pressed during active system OS is put into sleep state Pressed when power LED is OS is started from sleep state green-blinking...
  • Page 73: Gbe Rj-45 Connector

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.4.4. GbE RJ-45 Connector Table 41: Pinout GbE RJ-45 Connector Signal Name Signal Name TX1+ TX3- TX1- TX2- TX2+ TX4+ TX3+ TX4- 8.4.5. LED Diagram of LAN Connectors Table 8: Status of LEDs from GbE RJ-45 Connector left LED: activity/link right LED: 10/100/1000 right...
  • Page 74: Com2 Rs-232/422/485 (Via Internal Cable Connection To Cn16, Option)

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.4.7. COM2 RS-232/422/485 (via internal cable connection to CN16, Option) Table 43: Pinout RS-232/422/485 Connector Half Duplex Full Dup- RS-232 RS-422 RS-485 lex RS-485 DATA- DATA+ www.kontron.com // 74...
  • Page 75: Flatclient Pro Skylake/Kaby Lake

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.5. Flatclient PRO Skylake/Kaby Lake Figure 19: Interfaces for Panel PC FlatClient PRO Skylake/Kaby Lake variant HDMI Earth stud DP connector Power connector 2x GbE 4x USB 3.0 Power/LEDs 8.5.1. Input Power Connector Figure 20: Input Power Shield Figure 21: Mating Connector...
  • Page 76: Power-Switch And Leds

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.5.2. Power-Switch and LEDs Figure 22: Power-Switch and LEDs Power LED Power On LED Drive Activity Table 44: Power LED (1) Signal No Power Green Active Green blinking Standby Table 45: Button Functions (2) Button Functions Activity Pressed during active system...
  • Page 77: Led Diagram Of Lan Connectors

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Signal Name Signal Name TX1+ TX3- TX1- TX2- TX2+ TX4+ TX3+ TX4- 8.5.5. LED Diagram of LAN Connectors Table 8: Status of LEDs from GbE RJ-45 Connector left LED: activity/link right LED: 10/100/1000 right left No LAN connectivity...
  • Page 78: Hdmi Connector

    FlatClient ECO and FlatClient PRO – Rev. 1.95 8.5.7. HDMI Connector Table 50: Pinout HDMI Connector Signal Name TMDS Data2+ TMDS Data2– TMDS Data1+ TMDS Data1– TMDS Data0+ TMDS Data0– TMDS Clock+ TMDS Clock– Reserved Reserved DDC_CLK DDC_DATA +5 V Power Hot Plug Detect www.kontron.com // 78...
  • Page 79: 9/ Installation And Start

    FlatClient ECO and FlatClient PRO – Rev. 1.95 9/ Installation and Start 9.1. Mounting Instructions (built-in-variant only) Fixation screw torque is 0,8 Nm +/- 0,2 Nm. Step Installation Description  Use mounting set with screws and clamping brackets  Lens head Screw Philips M4x12 ...
  • Page 80: Startup Procedure

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Step Installation Description  Fix the bracket with the screw to the housing  Repeat step 4 for all positions of clamping bracket Wall-/Switch cabinet doors thickness has to be at least 3 mm. Otherwise use an adapter frame or adapter brackets.
  • Page 81 FlatClient ECO and FlatClient PRO – Rev. 1.95 All essential drivers you´ll find on www.snt-embedded.de www.kontron.com // 81...
  • Page 82: 10/ Technical Support

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Technical Support For technical support contact our Support Department:  E-mail: support@kontron.com  Phone: +49-821-4086-888 Make sure you have the following information available when you call:  Product ID Number (PN),  Serial Number (SN) The serial number can be found on the Type Label, located on the product’s rear side.
  • Page 83 FlatClient ECO and FlatClient PRO – Rev. 1.95 The goods for repair must be packed properly for shipping, considering shock and ESD protection. Goods returned to Kontron Europe GmbH in non-proper packaging will be considered as customer caused faults and cannot be accepted as warranty repairs. Include the RMA-Number with the shipping paperwork and send the product to the delivery address provided in the RMA form or received from Kontron RMA Support.
  • Page 84: Appendix A: List Of Acronyms

    FlatClient ECO and FlatClient PRO – Rev. 1.95 Appendix A: List of Acronyms Application Programming Interface Base Management Controller Command-Line Interface Computer-on-Module Error Checking and Correction Field Replaceable Unit Graphics Processing Unit HD/HDD Hard Disk /Drive PICMG Hardware Platform Management specification family Internet of Things Keyboard Controller Style...
  • Page 85: About Kontron

    FlatClient ECO and FlatClient PRO – Rev. 1.95 About Kontron Kontron is a global leader in Embedded Computing Technology (ECT). As a part of technology group S&T, Kontron offers a combined portfolio of secure hardware, middleware and services for Internet of Things (IoT) and Industry 4.0 applications. With its standard products and tailor-made solutions based on highly reliable state-of-the-art embedded technologies, Kontron provides secure and innovative applications for a variety of industries.

This manual is also suitable for:

Kontron flatclient ecoKontron flatclient pro

Table of Contents