Safety Notes; Operation; Specifications - Monacor PSS-600E Quick Start Manual

Switch mode power supply unit
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 2
PSS-600E
PSS-1000E
PSS-1500E
ELECTRONICS FOR SPECIALISTS
Switch Mode Power Supply Unit
These instructions are intended for users without any
specific technical knowledge. Please read these instruc-
tions carefully prior to operation and keep them for later
reference.
1 Applications
This power supply unit is used for direct current supply of small
units with an operating voltage between 3.0 V and 12.0 V and
a maximum current consumption of:
PSS-600E 0.6 A
PSS-1000E 1.0 A
PSS-1500E 1.5 A
The output voltage is adjustable to 3.0 V, 4.5 V, 5.0 V, 6.0 V, 7.5 V,
9.0 V or 12.0 V. The unit is protected against short circuit, over-
load and overheating. The special feature of the power supply
unit is its extra low current consumption (< 0.10 W) when the
unit connected has been switched off.

2 Safety Notes

This unit corresponds to all relevant directives of the EU and is
therefore marked with
WARNING
The unit uses dangerous mains voltage.
Leave servicing to skilled personnel only.
Inexpert handling unit may result in electric
shock.
The unit is suitable for indoor use only. Protect it against
dripping water and splash water, high air humidity and heat
(admissible ambient temperature range 0 – 40 °C).
Do not operate the unit and immediately disconnect the
mains plug from the mains socket
1. if there is visible damage to the unit or to the mains cable,
2. if a defect might have occurred after the unit was dropped
or suffered a similar accident,
3. if malfunctions occur.
In any case the unit must be repaired by skilled personnel.
For cleaning only use a dry, soft cloth; never use chemicals
or water.
No guarantee claims for the unit and no liability for any
resulting personal damage or material damage will be
accepted if the unit is used for other purposes than originally
intended, if it is not correctly connected, if it is overloaded or
if it is not repaired in an expert way.
If the unit is to be put out of operation defini-
tively, dispose of the unit in accordance with local
regulations.
Positive pole at the tip or at
the inner contact
Order number 0273030
Order number 0273130
Order number 0273140
ELECTRONICS FOR SPECIALISTS
.
Negative pole at the tip or
at the inner contact
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
Copyright
by MONACOR INTERNATIONAL. All rights reserved.
©
ELECTRONICS FOR SPECIALISTS

3 Operation

1) Determine the operating voltage of the unit to be supplied
with power (
marking of the power supply jack of the
unit) and adjust the voltage by turning the switch (3) with
the key supplied (2).
2) Select the matching adapter from the 7 adapters supplied:
Type
Diameter
2.5 mm
Plug
3.5 mm
outside
2.35 mm
3.5 mm
Hollow
5.0 mm
plug
5.5 mm
5.5 mm
3) Determine the position of the positive and negative poles at
the power supply jack of the unit to be connected (
ing of the jack) and connect the adapter to the inline jack (1)
accordingly.
With this marking or a similar marking of the power
supply jack, the positive pole must be at the tip or at the
inner contact of the adapter: Connect the adapter to the
inline jack in such a way that the arrow of the inline jack
will point to the number / numbers of the adapter (fig.
With this marking, the negative pole must be at
the tip or at the inner contact of the adapter: Connect the
adapter to the inline jack in such a way that the arrow of the
inline jack will point to the identification letter (fig.
4) Use the correct adapter to connect the power supply unit
to the unit to be supplied with power; then connect it to
a mains socket (100 – 240 V, 50 / 60 Hz). The red power LED
will light up.

4 Specifications

The specifications can be found on a separate sheet.
Subject to technical modification.
1
Identification letter
A
B
inside
0.75 mm
S
1.35 mm
H
2.1 mm
D
2.1 mm
E
2.5 mm
G
2
KEY
3
A-0943.99.06.08.2020
 mark-
).
).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pss-1000ePss-1500e027303002731300273140

Table of Contents