Adamson CS Series User Manual page 8

Hide thumbs Also See for CS Series:
Table of Contents

Advertisement

S
E
R
I
E
S
Power
RMS Long-Term
RMS Idle
Peak
Table 1 - Single cabinet current draw
Current draw for the CS119 is dynamic and fluctuates as operating levels change.
The CS Power Distribution Sysytem (PDS, 914-0002 - 110 V/914-0003 - 230 V) provides six individually
protected AC circuits of 208/230 V, 16 A power. When using the Adamson PDS, you can link a maximum of
three CS119 loudspeakers per circuit.
When wiring an AC cable for use with this product in
a single-line system, use the wiring scheme described
below in Table 2 and illustrated with Fig. 1. All work
must be completed by a qualified technician.
powerCON True1 AC Cable Input Connector
User Manual
100 V
115V
9.20 A
8.00 A
1.04 A
0.90 A
55.20 A
48.00 A
Hot or Live (L)
Neutral (N)
Protective Earth /
Ground (E or PE)
Table 2
120 V
208 V
230 V
7.67 A
4.42 A
4.00 A
0.86 A
0.50 A
0.45 A
46.00 A
26.54 A
24.00 A
Blue
Brown
Blue
Green and Yellow
powerCON True1 AC Cable Output Connector
240 V
3.83 A
0.43 A
23.00 A
Green and Yellow
Brown
Fig. 1
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs119

Table of Contents