 Liquids used must be as thin as water. Thicker liquids will
not spray properly.
 Do not overfill the tank.
NOTE: If using a measuring container or funnel to fill the
tank, be sure to thoroughly clean and rinse these items after
use. If premixing the spraying solution, rinse the container
used for mixing.
To fill:
 Turn off the electrostatic function and remove the battery
from the unit.
 Unscrew the cap and remove it from the tank.
 Fill the tank with the desired liquid, up to 1/2 gal.
NOTE: To ensure proper operation of the sprayer, DO
NOT fill past the max fill line.
 Screw the cap back onto the sprayer, making sure it is
tightened securely.
NOTE: Wipe the outside of the tank with a dry cloth and
clean up any spills before inserting the tank.
 Reinstall the battery pack.
NOTICE:
It is important to thoroughly clean the unit after each use.
Allowing liquid to remain in an idle tool for an extended
period may cause its moving pieces and connectors to
seize up.
INSTALLING/REMOVING BATTERY PACK
See Figure 4.
WARNING:
Always remove battery pack from your tool when you are
assembling parts, making adjustments, cleaning, or when
not in use. Removing battery pack will prevent accidental
starting that could cause serious personal injury.
To install:
 Align the grooves on the battery pack with the raised ribs
in the battery port and place the battery pack in the tool.
 Make sure the latches on each side of the battery pack
snap in place and that the battery pack is secured in the
tool before beginning operation.
To remove:
 Turn off the electrostatic function and remove the battery
from the unit.
 Depress the latches on both sides of the battery pack to
release the battery pack and remove it from the tool.
For complete charging instructions, see the operator's manu-
als for your battery pack and charger.
OPERATION
Risk of fire or explosion. Spray area must be well-
ventilated and away from sparks or flames.
USING THE ANTI-STATIC STRAP
See Figure 5.
Do not use this sprayer or enter the spray area if you have
a pacemaker, implantable cardioverter defibrillator (ICD),
internal pump, or any other similar medical device. Do not
use on or near electrical medical equipment.
Wear shoes with a leather sole while using this sprayer.
Do not wear shoes with a rubber sole, or similar insulat-
ing footwear.
The anti-static strap must be worn by the user at all times
during use.
 Slip the anti-static band onto your wrist or arm.
 Lift the locking tab and pull the end of the strap to tighten
as needed.
 After adjusting, lower the locking tab to secure to the
strap.
 The anti-static strap must be fastened to the user in a
place that makes direct contact with the user's skin.
 If the anti-static strap placement interferes with gloves or
similar protective equipment, the anti-static strap must
be worn underneath the protective equipment.
 If the anti-static strap becomes disconnected or damaged
in any way, stop the sprayer and follow the instructions
for replacing the strap in the Maintenance section.
 The anti-static strap should not be worn while performing
maintenance.
 The electrostatic function must be turned off before the
anti-static strap is removed.
TURNING THE SPRAYER ON/OFF
See Figure 6.
 To turn the sprayer ON, depress the switch trigger.
 To turn the sprayer OFF, release the switch trigger.
NOTE: If the sprayer has trouble priming or won't spray when
the tank is filled, the pump has lost its prime. Turn the nozzle
9 — English
WARNING:
WARNING:
CAUTION:
CAUTION: