Installation Instructions

Your air conditioner is designed to install in standard
double hung windows with opening widths of 23 to 36
inches (584 mm to 914 mm) (FIG. 1)
Lower sash must open sufficiently to allow a clear vertical
opening of 14-1/2 inches (368 mm). Side louvers and the
rear of the AC must have clear air space to allow
enough airflow through the condenser, for heat removal.
The rear of the unit must be outdoors, not inside a
building or garage.
NOTE:
SAVE CARTON and these INSTALLATION
INSTRUCTIONS for future reference. The carton is the
best way to store unit during winter, or when not in use.
Some assembly is required. Please read these instructions
carefully.
Mounting Hardware
TOOLS NEEDED:
Phillips Screw Driver
Drill (If pilot holes are needed)
SZ000354(En)
1
READ BEFORE INSTALLING UNIT
MS II Window Mounting
Qty.
3/4"screws
7
lock frame
2
sash lock
1
CAUTION
When handling unit, be careful to avoid cuts
from sharp metal edges and aluminum fins on
front and rear coils.
Before installing unit, the top rail must be
assembled on the unit.
Top Rail Hardware
TOOL NEEDED:
Phillips Screwdriver
A. Remove the air
conditioner from the
carton and place on a
flat surface.
B. Remove top rail from
the bottom of the
packaging material as
shown in Fig. A
C. Align the hole in the
top rail with those in
the top of the unit as
shown in Fig. B
D. Secure the top rail to
the unit with the 3/8"
Screws as shown in
Fig. C
NOTE: FOR SAFETY REASONS, ALL
FOUR (4) SCREWS MUST BE SECURELY
FASTENED.
1
10/21/2004, 10:43 AM
Qty.
3/8" Screw
4
Top Rail
1
Packaging
Fig. A
Top Rail
Fig. B
Fig. C

Advertisement

loading

Summary of Contents for Frigidaire FAA087P7A

  • Page 1: Installation Instructions

    Installation Instructions READ BEFORE INSTALLING UNIT Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches (584 mm to 914 mm) (FIG. 1) Lower sash must open sufficiently to allow a clear vertical opening of 14-1/2 inches (368 mm).
  • Page 2: How To Install

    D. Slide the panel all the way in and repeat on the other side. NOTE: If storm window blocks AC, see FIG. 12. Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill (FIG.
  • Page 3: If Ac Is Blocked By Storm

    Remove screws installed through frame and frame lock. Close (slide) side panels into frame. Keeping a firm grip on air conditioner, raise sash and carefully “rock” air conditioner backward to drain any condensate water in base of unit. Be careful not to spill any remaining water while lifting unit from window.