|nstallation
instructions
READ BEFORE iNSTALLiNG UNiT
MS II Window Mounting
Your air conditioner is designed to install in standard
double hung windows with opening widths of 23 to 36
inches (584 mm to 914 mm) (FIG. 1)
Lower sash must open sufficiently to allow a clear vertical
opening of 14 inches (356 mm). Side louvers and the
rear of the AC must have clear air space to allow
enough airflow through the condenser, for heat removal.
The rear of the unit must be outdoors, not inside a
building or garage.
Fig. 1
EXTERIOR
NOTE:
SAVE CARTON and these INSTALLATION
INSTRUCTIONS for future reference. The carton is the
best way to store unit during winter, or when not in use.
Some assembly is required. Please read these instructions
carefully.
,f
Mounting
Hardware
3/4" screws
lock flame
sash lock
TOOLS
NEEDED:
• PhillipsScrewDriver
, Drill(Ifpilotholesareneeded)
NOTE: DO NOT USE ANY SCREWS OTHER THAN
THOSE SPECIFIED HERE
When handling unit, be careful to avoid cuts
from sharp metal edges and aluminum fins on
front and rear coils.
Before
installing
unit, the top rail must
be
assembled
on the unit.
Top Rail Hardware
Qty.
3/8" Screw
4
Top Rail
l
TOOL
NEEDED:
,
Phillips Screwdriver
Top
Rail
A. Remove the air
conditioner from the
carton and place on a
fiat surface.
Packaging
B. Remove top rail from
the rear of the
packaging material as
shown in Fig. A
D,
Align the hole in the
top rail with those in
the top of the unit as
shown in Fig. B
Secure the top rail to
the unit with the 3/8"
Screws as shown in
Fig. C
NOTE:
FOR
SAFETY
REASONS,
ALL
FOUR
(4) SCREWS
MUST
BE SECURELY
FASTENED.
P/N 2020213A0322

Advertisement

loading

Summary of Contents for Frigidaire FAA087S7AF

  • Page 1 |nstallation instructions READ BEFORE iNSTALLiNG UNiT MS II Window Mounting Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches (584 mm to 914 mm) (FIG. 1) When handling unit, be careful to avoid cuts Lower sash must open sufficiently to allow a clear vertical from sharp metal edges and aluminum fins on opening of 14 inches (356 mm).
  • Page 2 How to Install NOTE: "Fop Rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of (5/16"). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained! Place unit on floor, a bench or a table.
  • Page 3 Place frame lock between the frame foam seal and insert in the space extensions and the window sill as shown between the upper lower sashes (riG.13). (Fig. 8). Drive 3/4" (19 ram) locking screws through frame lock into the sill (FIG.