ABB EDS500 Series Operating Instruction page 2

Ethernet & dsl switches
Hide thumbs Also See for EDS500 Series:

Advertisement

Pin allocation serial interface RS-232 (RJ-12)
RS-232
Pin
Signal D irection Pin
1
DCD Output
2
CTS Output
3
RTS Input
6
1
4
GND -
5
RxD Output
6
TxD Input
Pin allocation serial interface RS-485 half duplex
(RJ-12)
RS-485 half duplex / 2-wire
Pin
Signal
1
2
3
B (-)
6
1
4
GND
5
6
A (+)
Pin allocation serial interface RS-485 full duplex
(RJ-12)
RS-485 full duplex / 4-wire
Pin
Signal
1
2
B (-)
3
B (-)
6
1
4
GND
5
A (+)
6
A (+)
Power connector (X1)
The EDS500 devices are equipped with a wide range
power supply for voltages between 24 and 60 Volts DC
(power consumption see device label). The connector
is a 4-pin Phoenix plug with screw terminals.
Pin allocation power supply (X1)
Pin
Signal
1
24-60 V DC
1
2
3
4
2
Functional earth (internally wired to
pin 4)
3
GND
4
Functional earth (internally wired to
pin 2)
A D V I C E
Due to the internal overvoltage protection,
interrupt any connection to ground of the device
for the time of the measurement before you carry
out isolation measurement. This includes the
earthing of the hat rail as well as all shields of all
transmission lines and supply feedings. RJ-12 plugs
or RJ-45 plugs can establish earthing via the shield.
Extension interface (EXT)
The plug of the proprietary expansion bus is designed
RS-232 PC SUB-D9
as USB type B but uses a manufacturer specific
Signal D irection
protocol.
1
DCD Input
The configuration parameters are stored directly
8
CTS Input
on the device. In addition, a configuration stick can
7
RTS Output
be connected to the expansion bus to save data
5
GND -
externally, in example to exchange defective devices
2
RxD Input
easily.
3
TxD Output
Direction
Alarm-Relay (X2)
The devices are equiped with a potential free alarm
bi-directional
output (relay with isolated switchover contact). This
-
output corresponds to a device alarm and is activated
when the device looses the power supply or the alarm
LED is constantly on. The reason for the signalling of
bi-directional
an alarm can be referenced in the system alarm table.
Pin allocation alarm output (X2)
Direction
Input
Output
-
Input
Output
Signaling
LED
Power
Ready
Fo Module
Fo Link
Fo Activity
Con DCD
A D V I C E
Danger of damaging the device
Do not connect any USB devices!
Pin
Signal
1
2
3
4
1 & 2 Normal state
1 & 3 Alarm state
4
Common contact (connected to 1)
W A R N I N G
The relay is designed for switching only safe low
voltages.
Description Function
Voltage
Supply
Ready
SFP Module
SFP link
SFP activity
Con DCD
off
Device is without
power supply
green
Power supply
switched on
off
Hardware fault or
booting
green
Device ready
off
SFP not plugged
green
SFP plugged
off
no optical link
active
green
Optical link estab-
lished
off
No activity on the
optical interface
green
Data is trans-
mitted via the
optical interface
off
DCD inactive on
Con interface
green
DCD active