Automatic Sliding Door Decals
Sliding doors servicing ingress or egress must be marked with directional decals. The arrow sign must
be visible from the approach side and an international "DO NOT ENTER" must be visible from the
other side. These door decals must be affixed on the door 50" +/‐ 12" from the finished floor.
KNOWING ACT DOORS – The door shall have signage which says "AUTOMATIC DOOR – ACTIVATE
SWITCH TO OPERATE" along with other required signage visible from each side of the door.
Required Decals Included:
A "Daily Safety Check" decal has also been provided as a reminder that your automatic door
equipment must be checked daily for safe operation. Affix this decal to the side of the jamb tube.
Certain jurisdictions require "This Door Must Remain Unlocked When the Building is Occupied" decal
affixed on all exit doors. This decal is not supplied as part of the decal kit.
Troubleshooting and Hints
Door(s) will not operate (will not open or close)
Is the power switch on? If not, turn it on.
PROBLEM:
ACTION:
If the power switch is on, the door(s) may need to be reset. This is done
by turning the power switch to the "OFF" position. Wait a few seconds,
turn back "ON" and allow the door to re‐tune itself. The door(s) will
open and close very slowly in a search mode and, if possible, the
door(s) should not be interrupted during the process. If traffic must go
through, door(s) will open at regular speed then when zone is clear,
door(s) will close at regular speed until they reach the point of
interruption then resume search mode (slow speed) until closed.
"AUT/CLS/OPN" (Auto/Close/Open) switch should be set to "AUT". If
set to "CLS", door(s) should close and remain closed – sensors are off. If
set to "OPN", door(s) should open and remain open.
Check all panels for breakout. Are all doors securely in place (not
broken out)? May require up to 50lbs. of force to push back in. Do they
manually slide all the way open and closed with little effort? If not, is
the track clean?
Toll Free: 800 7 ACCESS (1 800 722-2377)
Service: 888-DOOR-444
Decals Ordered Separately:
P/N 511164
P/N 511165
203918 Rev. D
11/2019
P/N 413743
Pg. 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dura-storm seriesDura-guard seriesDurafit series

Table of Contents