Automatic Sliding Door Decals; Troubleshooting And Hints - Stanley Dura-Glide Series Owner's Operation And Maintenance Manual

Automatic slide door systems
Hide thumbs Also See for Dura-Glide Series:
Table of Contents

Advertisement

 
Automatic Sliding Door Decals 
 
Sliding doors servicing ingress or egress must be marked with directional decals. The arrow sign must 
be visible from the approach side and an international "DO NOT ENTER" must be visible from the 
other side.  These door decals must be affixed on the door 58" +/‐5" from the finished floor. 
 
KNOWING ACT DOORS – The door shall have signage which says "AUTOMATIC DOOR – ACTIVATE 
SWITCH TO OPERATE" along with other required signage visible from each side of the door. 
 
 
 
 
Decals included:  
 
 
 
 
A "Daily Safety Check" decal has also been provided as a reminder that your automatic door 
equipment must be checked daily for safe operation. Affix this decal to the side of the jamb tube. 
Certain jurisdictions require "This Door Must Remain Unlocked When the Building is Occupied" 
decal affixed on all exit doors.  This decal is not supplied as part of the decal kit. 
 
Troubleshooting and Hints 
 
PROBLEM:  Door(s) will not operate (will not open or close) 
ACTION: 
Is the power switch on?  If not, turn it on. 
 
 
If the power switch is on, the door(s) may need to be reset.  This is done by turning the 
power switch to the "OFF" position.  Wait a few seconds, turn back "ON" and allow the 
door to re‐tune itself.  The door(s) will open and close very slowly in a 
search mode and, if possible, the door(s) should not be interrupted 
during the process.  If traffic must go through, door(s) will open at 
regular speed then when zone is clear, door(s) will close at regular 
speed until they reach the point of interruption then resume search 
mode (slow speed) until closed. 
 
 
"AUT/CLS/OPN" (Auto/Close/Open) switch should be set to "AUT".  If 
set to "CLS", door(s) should close and remain closed – sensors are off.  If 
set to "OPN", door(s) should open and remain open. 
 
 
Check all panels for breakout.  Are all doors securely in place (not 
broken out)? May require up to 50lbs. of force to push back in.  Do they 
manually slide all the way open and closed with little effort?  If not, is 
the track clean? 
 
6
Decals Ordered 
Separately: 
 
P/N 413743 
P/N 511164  P/N 511165 

Hide quick links:

Advertisement

Table of Contents
loading