LG Multi F Series Installation Manual page 67

Outdoor unit
Hide thumbs Also See for Multi F Series:
Table of Contents

Advertisement

Figure 84: Multi F LMU30CHV and LMU36CHV System Power Wiring and Communications Cable.
L1
L2
Power Supply
Main Switch
Circuit Breaker
Three-wire Power Wiring
(Including Ground)
1(L1)
2(L2)
Indoor Unit Terminal Block
Unit A
POWER WIRING
COMMUNICATIONS CABLE
• All field-supplied wiring, components, and materials must comply with all applicable national, state, and local codes and requirements.
Improper wiring will result in fire, electric shock, physical injury or death.
• Ground wiring is required to prevent accidental electrical shock during current leakage, communication problems from electrical noise, and
motor current leakage.
Do not connect the ground line to the pipes. There is a risk of fire, electric shock, explosion, physical injury or
death.
• Install a main shutoff switch or circuit breaker that interrupts all power sources simultaneously. There is a risk of fire, electric shock, explo-
sion, physical injury or death.
• All field-supplied wiring, components, and materials must comply with all applicable national, state, and local codes and requirements.
Failure to install proper electrical components can result in property damage and equipment malfunction.
• Ground wiring is required to prevent communication problems from electrical noise, and motor current leakage. Failure to provide proper
ground wiring can result in property damage and equipment malfunction.
• Install a main shutoff switch or circuit breaker that interrupts all power sources simultaneously. Failure to install proper electric components
can result in property damage and equipment malfunction.
• Maintain polarity throughout the communication network. The system will malfunction if not properly wired.
G
L1
L2
G
Fuse
3
1(L1)
2(L2)
3
Indoor Unit Terminal Block
Unit B
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Outdoor Unit
Outdoor Unit Terminal Block
L1 L2
1(L1) 2(L2) 3(A)
1(L1) 2(L2)
3(B)
G
G
1(L1)
2(L2)
3
Indoor Unit Terminal Block
Unit C
ELECTRICAL
1(L1)
2(L2)
3(C)
1(L1)
2(L2)
3(D)
G
G
1(L1)
2(L2)
3
Indoor Unit Terminal Block
Unit D