Will Burt 5438901 Operator's Manual

Will Burt 5438901 Operator's Manual

Night scan spot

Advertisement

Quick Links

'
N
S
S
O
M
IGHT
CAN
POT
PERATOR
S
ANUAL
(P/N: 5438901)
The Will-Burt Company
401 Collins Boulevard
Orrville, OH 44667
www.willburt.com
TP-5590101-00, June 2019
© 2019 The Will-Burt Company
Original Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Will Burt 5438901

  • Page 1 ’ IGHT PERATOR ANUAL (P/N: 5438901) The Will-Burt Company 401 Collins Boulevard Orrville, OH 44667 www.willburt.com TP-5590101-00, June 2019 © 2019 The Will-Burt Company Original Instructions...
  • Page 3 ’ IGHT PERATOR ANUAL Warranty Will-Burt warrants its Night Scan Spot to be free from defects in material and workmanship for a period of five (5) years with such time periods running from the date of shipment by Will-Burt. Will-Burt shall not be responsible for any damage resulting to or caused by its products by reason of failure to properly install, maintain or store the product;...
  • Page 4 ’ IGHT PERATOR ANUAL Document History Document Numbers Dates Remarks TP-5590101-00 June 17, 2019 Initial Release TP-5590101-00 June 2019...
  • Page 5: Table Of Contents

    ’ IGHT PERATOR ANUAL Table of Contents Safety Summary ........................iii General Safety Instructions ........................iii Section 1 Introduction ......................1 1.1 Safety Precaution Notification ......................1 1.2 Manual Organization ........................... 1 1.3 Specifications ............................2 1.4 Night Scan Spot Description ....................... 2 Section 2 Installation .......................
  • Page 6 ’ IGHT PERATOR ANUAL TP-5590101-00 June 2019...
  • Page 7: Section 1 Introduction

    ’ IGHT PERATOR ANUAL Section 1 Introduction Review this manual in its entirety. Contact The Will-Burt Company with any questions before performing any procedure outlined in this manual. The views depicted in this manual are provided for clarification and are subject to change without notice. Views are not to scale. This manual describes installation, operation, and maintenance procedures for the Night Scan Spot.
  • Page 8: Specifications

    ’ IGHT PERATOR ANUAL 1.3 Specifications Table 1 Night Scan Spot Specifications Functional Characteristic Specification 10 – 30 VDC Operating Voltage Range Power Consumption Maximum Distance for Operating Remote Control Up to 130 ft. Approximate Weight 7 lb. (3.2 kg) Remote Control Battery One 23A battery (12V) 1.4 Night Scan Spot Description...
  • Page 9: Section 2 Installation

    ’ IGHT PERATOR ANUAL The Night Scan Spot is equipped with a flashing alert feature which can be used:  To warn approaching motorists of pedestrians of potential hazards  To alert that help is needed  With service vehicles to alter on-coming vehicles that there are people at work The Stow Feature causes the light to automatically turn to face the forward position when turned off.
  • Page 10: Section 3 Operation

    ’ IGHT PERATOR ANUAL 8. Secure the Remote Control Holder in position using both mounting holes with customer- provided stainless steel hardware. The mounting hardware must include proper means to resist vibration loosening such as thread-locking compound or locking hardware. Torque all hardware as appropriate for its size and grade.
  • Page 11: Section 4 Remote Control Pairing

    ’ IGHT PERATOR ANUAL Section 4 Remote Control Pairing The default state for the Night Scan Spot is to be unpaired to any Remote Control. To avoid interference from other Remote Control devices that are within range, it is highly recommended that the light be paired to a Remote Control.
  • Page 12: Section 5 Maintenance

    ’ IGHT PERATOR ANUAL Section 5 Maintenance As needed, use a clean, soft cloth, mild soap, and water to clean the lens. Note: The Night Scan Spot uses Lexan lenses and cleaning with abrasive materials, solvents, or most chemical cleaners can cause lens surface degradation and reduce performance of the light.

Table of Contents