Ediseja 21 CMU 100 Series User Manual

Rs485 to singlemode fiber optic converter
Hide thumbs Also See for CMU 100 Series:

Advertisement

Quick Links

Company:
Device:
Ediseja 21 CMU 100 / 1.5.S - 0
RS485 to Singlemode
Fiber Optic Converter
CMU 100 / 1.5.U - 0
CMU 100 / 7.5.U - 0
Document:
Code:
User manual CMUMU15S
CMU 100
User Manual
CMU 100 / 1.5.S - 0
CMU 100 / 7.5.S - 0
CMU 100 / 1.5.T - 0
CMU 100 / 7.5.T - 0
Date:
01.09.2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMU 100 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Ediseja 21 CMU 100 Series

  • Page 1 CMU 100 / 1.5.T - 0 CMU 100 / 7.5.T - 0 CMU 100 / 1.5.U - 0 CMU 100 / 7.5.U - 0 Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 2: Table Of Contents

    3.4.3 SINGLEMODE FIBER OPTIC INTERFACE BOARD............11 SCHEMATIC....................12 INSTALLATION....................13 5.1 INSTALLATION........................13 COMMISSIONING & MAINTENACE............15 6.1 COMMISSIONING......................15 6.2 MAINTENANCE......................... 15 TECHNICAL DATA..................16 DIMENSIONS....................18 ORDERING....................19 Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 3: Preface

    Tel: 00 386 51 643 411, 051 643 411 Email: grega.flander@ediseja21.com www.ediseja21.com Copyright Copyright © Ediseja 21, 2019. All rights reserved. Explanation of the symbols Read the instructions! Device was tested with 2,5 kV AC voltage to check the device insulation. Device ground terminal.
  • Page 4 If device is damaged disconnect it from power supply! Send it to the manufacturer for inspection. Warning! Connect to earth before attaching power supply! Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 5: Cmu 100 System

    All settings on the device can be made from outside by a DIL switch. It is not necessary to open the housing. Company: Device: Document: Code: Date: Page: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 6 CMU 100 - RS485 to Singlemode Fiber Optic Converter Picture 1: CMU 100 system general diagram Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 7: Rs485 To Singlemode Fiber Optic Converter

    Fiber optic communication allows longer distances between devices without electromagnetic disturbances. TYPICAL APPLICATION Picture 2: Typical application Company: Device: Document: Code: Date: Page: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 8: Appearance

    Hardware settings For proper functioning of that board some settings must be done: Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 9 Switches at the upper side of connector: BAUD rate bit/s Switch Interface 5 Interface M Interface L 19200 4800 38400 9600 57600 19200 1200 Company: Device: Document: Code: Date: Page: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 10 Connector pin table MSTB - (B) + (A) Description Picture 5: RS485 interface board appearance with switch settings Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 11: Singlemode Fiber Optic Interface Board

    Radiation emitted by single mode laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Picture 7: Singlemode fiber optic interface board appearance Company: Device: Document: Code: Date: Page: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 12: Schematic

    CMU 100 - RS485 to Singlemode Fiber Optic Converter SCHEMATIC Picture 8: General diagram Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 13: Installation

    Protective earthing wire must be terminated with tinned copper ear terminal.  The prescribed bending radius of the optical fibre cables must be observed.  Company: Device: Document: Code: Date: Page: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 14 CMU 100 - RS485 to Singlemode Fiber Optic Converter Picture 9: left. installation, right: deinstallation Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 15: Commissioning & Maintenace

    If single mode fiber optic interface is used, do not look into the laser beam.  MAINTENANCE The device is maintenance-free. Disconnect power supply before cleaning it. Use moist cloth. Do not use liquids. Company: Device: Document: Code: Date: Page: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 16: Technical Data

    1200 m Isolation 1000 V DC Connector type „MSTB“ Phoenix 3pin Termination 120 Ohm Max number of devices on RS485 bus Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 17 Humidity operating up to 95 % (noncondensing) Material Enclosure standard DIN 35 rail (acc. to DIN EN 50022) Mount type Class Overvoltage category Company: Device: Document: Code: Date: Page: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 18: Dimensions

    CMU 100 - RS485 to Singlemode Fiber Optic Converter DIMENSIONS Picture 10: Dimensions Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 19: Ordering

    - power supply cable with „schuko“ plug, 2 m - RS232 cable to PC (state the lenght up to 15 m) - fiber optic cables (state the lenght) Company: Device: Document: Code: Date: Page: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 20 CMU 100 / 2.1.1.S - 12 20 km, 19200-115200 bit/s, high voltage power FO SM RS232 RS485 CMU 100 / 2.1.5.S - 12 supply Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 21 CMU 100 / 2.6.6.6.6.6 - 12 5 x FO MM Multimode fiber optic to 5 x multimode FO CMU 100 / 2.6.6.6.6.6.6 - 12 Company: Device: Document: Code: Date: Page: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...
  • Page 22 Ediseja 21, razvoj elektronskih naprav, d.o.o. Stegne 21C 1000 Ljubljana Slovenia – EU Tel: 00 386 51 643 411, 051 643 411 grega.flander@ediseja21.com www.ediseja21.com Page: Company: Device: Document: Code: Date: Ediseja 21 CMU 100 / 1.5.S - 0 User manual CMUMU15S 01.09.2019...

Table of Contents