I N S T A L L A T I O N
1. Determine the vertical centerline of the door lock face and
the horizontal centerline of the latch.
IMPORTANT: When determining the horizontal centerline
observe the following:
FOR MORTISE LOCKS: Align the angled ramps of the lip
bracket with the deadlock trigger of the mortise latch.
FOR CYLINDRICAL LOCKS: Align the center of the latch with
the center of the strike opening.**
2. Transfer both the horizontal and vertical centerlines to the
doorframe.**
3. Prepare the doorframe for cutting as per the appropriate
drawing.
4. If required, install "no weld" mounting brackets as per the
instructions included with the mounting brackets in the
hardware pack.
7104, 7304
Aluminum & Wood Frames, 1-1/2" D
4104, 4304
Aluminum Frames, 1-1/2" D
Any modular A41, A43, A71 or A73
with B4704 faceplate
A
1-1/4
1.250
31.75
B
4-7/8
4.875
123.83
C
3-3/8
3.375
85.73
D
7/8
.875
22.23
E
3/8
.375
9.53
F
1/8*
.125*
3.18*
G 1-11/16
1.688
42.86
Vertical
Vertical Vertical
Vertical Centerline
X
C/L
C/L
C/L
of Door**
Door
Door
Door
R
5/32
.156
3.97
K
4-1/8
4.125
104.78
M 12-24
†
—
—
NOTE: Specifications subject to change without notice.
* Dimension F is measured from face of mounting tab to face of frame and equates to the thickness of the frame material.
**Dimension X on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be
necessary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness to Dimension X to
relocate the vertical centerline an appropriate distance on the frame.
†
For wood frame door installations, substitute #12 wood screws for dimension M.
IS47A
USA: 2697 INTERNATIONAL PARKWAY, PKWY 5, VIRGINIA BEACH, VA 23452 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON N1T 1J6
PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: SALES@RUTHERFORDCONTROLS.COM
®
Instructions
©2008 RUTHERFORD CONTROLS INT'L CORP. WWW.RUTHERFORDCONTROLS.COM
5. Attach the strike insert (coil unit or "motor") to the lip
bracket with the screws provided.
6. Attach the strike faceplate to the lip bracket with the screws
provided. (It may be desirable to leave these screws slightly
loose to facilitate insertion into the doorframe.
7. Connect the incoming wiring from the power supply to the
terminal screws on the strike insert. RCI door strikes are not
polarity sensitive although be certain to observe proper
polarity if a suppression diode is required for access control
applications.
8. Install the door strike in the doorframe using the screws
provided.
7105, 7305
Aluminum & Wood Frames, 1-1/2" D
4105, 4305
Aluminum & Wood Frames, 1-1/2" D
Any modular A41, A43, A71 or A73
with B4705 faceplate
A
1-1/8
1.125
28.58
B
5-7/8
5.875
149.23
C
3-3/8
3.375
85.73
D
7/8
.875
22.23
E
1/4
.250
6.35
F
1/8*
.125*
3.18*
G 1-11/16
1.687
42.86
Vertical Vertical Vertical
Vertical Centerline
X
C/L
C/L
C/L
of Door**
Door
Door
Door
R
5/32
.156
3.97
K
5-3/8
5.375
136.53
M
12-24
†
—
—
4 /7 Series
Electric Strikes
PCN080047
P10/08DA