  • Page 1 ELECTRIC/HYDRAULIC PUMPS UP-65SV(G) Series Operation and maintenance manual NITTOH ZOHKI CO.,LTD. 102,4-10,2-Chome,Kamezawa,Sumida-ku, Tokyo 130,Japan Telephone.03-3625-6551 Facsimile. 03-3625-6553...
  • Page 2: Table Of Contents

    INDEX 1. Safety information ---------------------------- 2 page 2. Description of components ------------------ 4 3. Instructions before use ----------------------- 5 4. Operation --------------------------------------- 5 5. Maintenance ------------------------------------ 6 6. Circuits ------------------------------------------10 7. Construction drawings ------------------------11 8. Parts lists ----------------------------------------13 9. Trouble shooting guide ------------------------15 Warranty -----------------------------------------16...
  • Page 3: Safety Information

    Read and follow all WARNINGS,CAUTIONS and INSTRUCTIONS included with each product to use the products correctly and to avoid personal injury or property damage during system operation. NITTOH ZOHKI CANN NOT BE RESPONSIBLE FOR DAMAGE OR INJYRY RESULTING FROM UNSAFE USE OF PRODUCTS, LACK OF MAINTENANSE OR INCORRECT SYSTEM APPLICATION.
  • Page 4 Caution when used WARNING ■Take safety measures. When hydraulic equipment is operated, protect yourself with a personal safeguard, working clothes and shoes, safety spectacles, etc. ■Always check pressure limitations of hydraulic circuit. Always confirm in advance that max. permissible working pressure of a hydraulic pump is lower than the pressure rating of the lowest rated component connected in the system.
  • Page 5: Description Of Components

    2 Description of components UP-65SVG-8H.8A ① Erectric motor ② Metal plug socket ③ Power supply plug ④ HP relief valve ⑤ Oil feeding plug ⑥ Reservoir ⑦ Oil gauge ⑧ Delivery port block ⑨ Pressure gauge ⑩ Pendant switch 2.5m ⑪...
  • Page 6: Instructions Before Use

    3 Instructions before use 3-1 Confirmation of all components for shipping damage or oil leakage. If any shipping damage is found, notify carrier at once. Shipping damage is not covered by warranty. The carrier is responsible for all repair or replacement costs resulting from damage in shipment.
  • Page 7: Maintenance

    5 Maintenance 5-1 Hydraulic working oil ① Kind of oil Use only Nittoh NHO-32 hydraulic oil or an approved, high-grade oil (ISO #32, viscosity : 32 cSt @40°C) with these pumps to promote long pump life. ② Oil temperature Aptitude temperature for use of hydraulic oil is max. 55 ° C. In case it happens unacceptable rise in oil temperature, stop working so as to decrease oil temperature or take such a measure as installation of an oil cooler.
  • Page 8 5-2 Pressure and piping ① Composition of hydraulic equipment system WARNING When a pump, high-pressure hose(s), cylinder, valve, couplings are connected together, always check product limitations regarding pressure ratings and load capacities. The system operating pressure must not exceed the pressure rating of the lowest rated component in the system.
  • Page 9 150 hours or more subject to the conditions of their uses. Use only NITTOH carbon brushes with these pumps to promote long pump life. When they have been worn down, the spring exerts insufficient pressure to hold brush against the commutator.
  • Page 10 Range of standard pressure adjustment available is form 58.8 to 68.6MPa. different kind of a spring is needed to adjust and set at lower pressure than the standard. Contact NITTOH authorized distributor. Loosen lock screw on the relief valve and turn the adjusting screw a few turns counter-clockwise to decrease pressure setting to a lower desired pressure.
  • Page 11: Circuits

    6 Circuits UP-65SVG-8A/8H Hydraulic Circuit Electric Circuit UP-65SVG-8SP/8WP Hydraulic Circuit Electric Circuit UP-65SVG-8R Hydraulic Circuit Electric Circuit...
  • Page 12: Construction Drawings

    7 Construction drawings The pump part is an attached sheet (Drawing attachment). The valve part mentions it according to a model as follows. UP-65SVG-8H/8A...
  • Page 13 VPCW-10 (UP-65SVG-8WP/8SP) Pilot check valve VDRL-10 (UP-65SVG-8R) Double relief valve...
  • Page 14: Parts Lists

    8 Parts list Part No. Description HL valve portion Driving portion φ5.55 Ceramic ball 1P50155 Pump body Spring TLA1616Z Bearing 4P53854 Copper packing AC0687A0 Oil seal Valve seat 4P53051 Low pres, piston Screw plug φ7 4P53052 High pres, piston Steel ball UF-8.5-20 Spring Spring...
  • Page 15 φ3×17.8F Push pin Tank portion 4P53489 Valve seat 1P50156 Reservoir 3L P-14 O ring KCM-20 Oil gauge P-14 Back-up ring G-140 O ring 4P53492 Valve seat retainer 8-10 φ1/4 Steel ball Spring washer 8-11 WL5-10 Spring M6×15 Fitting bolt 8-12 P-14 O ring PN-3/8...
  • Page 16: Trouble Shooting Guide

    9 Trouble shooting guide WARNING ●To prevent injuries, any repair work or trouble-shooting must be done by qualified personel familiar with this kind of equipment. Use the proper gauges and device. Problems Possible Causes Remedies Motor does not run (1) No supply voltage. (1) Check line voltage.
  • Page 17: Warranty

    It is for one year from purchase. 9-2 Warranty All NITTOH products and parts, with the exception mentioned below, are warranted against defects in materials and workmanship, which results in damage to products and parts. This warranty shall cover repair and/or replacement of the products or components/parts free of charge.