Nittoh UP-35RH-NC Operation And Maintenance Manual

Electric/hydraulic pumps

Advertisement

Quick Links

ELECTRIC/HYDRAULIC PUMPS
UP-35RH-NC(L)
UP-35RH-NO(L)
UP-35RH-AR(L)
Operation and maintenance manual
NITTOH ZOHKI CO.,LTD.
102,4-10,2-Chome,Kamezawa,Sumida-ku,
Tokyo 130,Japan
Telephone.03-3625-6551
Facsimile. 03-3625-6553

Advertisement

Table of Contents
loading

Summary of Contents for Nittoh UP-35RH-NC

  • Page 1 ELECTRIC/HYDRAULIC PUMPS UP-35RH-NC(L) UP-35RH-NO(L) UP-35RH-AR(L) Operation and maintenance manual NITTOH ZOHKI CO.,LTD. 102,4-10,2-Chome,Kamezawa,Sumida-ku, Tokyo 130,Japan Telephone.03-3625-6551 Facsimile. 03-3625-6553...
  • Page 2: Table Of Contents

    INDEX 1. Safety information ---------------------------- 2 page 2. Description of components ------------------ 4 3. Instructions before use ----------------------- 4 4. Operation --------------------------------------- 5 5. Maintenance ------------------------------------ 5 6. Circuits ----------------------------------------- 11 7. Construction drawings ----------------------- 11 8. Parts lists --------------------------------------- 12 9.
  • Page 3: Safety Information

    Read and follow all WARNINGS,CAUTIONS and INSTRUCTIONS included with each product to use the products correctly and to avoid personal injury or property damage during system operation. NITTOH ZOHKI CANN NOT BE RESPONSIBLE FOR DAMAGE OR INJYRY RESULTING FROM UNSAFE USE OF PRODUCTS, LACK OF MAINTENANSE OR INCORRECT SYSTEM APPLICATION.
  • Page 4: Specifications

    Caution when used WARNING ■Take safety measures. When hydraulic equipment is operated, protect yourself with a personal safeguard, working clothes and shoes, safety spectacles, etc. ■Always check pressure limitations of hydraulic circuit. Always confirm in advance that max. permissible working pressure of a hydraulic pump is lower than the pressure rating of the lowest rated component connected in the system.
  • Page 5: Description Of Components

    2 Description of components ① Carying belt ② Electric motor ③ Carbon brush ④ Tank cover ⑤ Relief valve ⑥ Power supply cord ⑦ Operation cord ⑧ Oil feeding plug ⑨ Delivery port PT3/8 ⑩ Pendant switch 3 Instructions before use 3-1 Confirmation of all components for shipping damage or oil leakage.
  • Page 6: Operation

    5 Maintenance 5-1 Hydraulic working oil ① Kind of oil Use only Nittoh NHO-32 hydraulic oil or an approved, high-grade oil (ISO #32, viscosity : 32 cSt @40°C) with these pumps to promote long pump life. ② Oil temperature Aptitude temperature for use of hydraulic oil is max. 55 ° C. In case color of the temperature seal attached to the tank has changed and indicated “55”...
  • Page 7 ③ Oil exchange CAUTION The frequency of oil change will depend upon general working conditions, severity of use and overall cleanliness. 300 hours (working time) of use or about 3 months is considered as a standard change interval. Periodically compare samples oh the reservoir oil with new oil and inspects oil color for contaminants or differences.
  • Page 8 5-3 High pressure hoses ① Hose installation WARNING Install hoses, leaving something in reserve, because high-pressure hoses expand and contract more or less when full pressure is applied. Be careful that the hoses do not rub against other solid materials. Never allow the hoses to kink, twist, curl or bend so tightly that oil flow within hoses are blocked or restricted.
  • Page 9 CAUTION 5-5 Bleeding air from the system Reservoirs of UP-35RH-Series pumps are made of totally enclosed rubber tanks and tank covers. Rubber tanks are filled with oil, making no room for air accumulation. However, in case a new cylinder and / or new hose is connected with the pump, or oil is exchanged, air may accumulate in the hydraulic system.
  • Page 10 ④ If the pump works normally, air in the hose, cylinder and other system is collected in the tank and oil must be replenished. ◎How air may accumulate in the pump (rubber tank) when hydraulic equipment are connected together with? Always check and confirm before use that the oil tank is full.
  • Page 11 150 hours or more subject to the conditions of their uses. Use only NITTOH carbon brushes with these pumps to promote long pump life. When they have been worn down, the spring exerts insufficient pressure to hold brush against the commutator.
  • Page 12: Circuits

    6 Circuits UP-35RH-NC Hydraulic Circuit Electric Circuit UP-35RH-NO Hydraulic Circuit Electric Circuit UP-35RH-AR Hydraulic Circuit Electric Circuit 7 Construction drawings...
  • Page 13: Parts List

    8 Parts list Part No. Description 2-17 Screw 3 MSWA-12-6 Driving portion 2-18 PT1/16 Blind plug 2P50296 Base plate 2-19 4P51460 Hi pressure blind cover AC0598A0 Oil seal 2-20 4P52529 Spacer 4P51380 Eccentric collar 2-21 4P54064 Retainer H Ball bearing RNAF223013 φ4×28 Spring pin...
  • Page 14 Relief valve portion 5-16 G-100 O ring M6×15 Tl8-15 Relief spring low 5-17 Fitting screw M12×P1.5 Lock nut 4P51889 Ball receiver Electrical parts portion TB8-15 Relief spring high Protection tube O ring Pendant control switch 4P51980 Relief spring retainer Power cord M5×5 Lock screw 3P50476...
  • Page 15: Trouble Shooting Guide

    9 Trouble shooting guide WARNING ●To prevent injuries, any repair work or trouble-shooting must be done by qualified personel familiar with this kind of equipment. Use the proper gauges and device. Problems Possible Causes Remedies Motor does not run (1) No supply voltage. (1) Check line voltage.
  • Page 16: Warranty

    It is for one year from purchase. 9-2 Warranty All NITTOH products and parts, with the exception mentioned below, are warranted against defects in materials and workmanship, which results in damage to products and parts. This warranty shall cover repair and/or replacement of the products or components/parts free of charge.