Summary of Contents for LS Control SpeedControl E 1047
Page 1
Frequency Converter SpeedControl E 1047 For use with specific motors Date: 10/12-2018 Revision: 1 Drawn by: FS and DF Manufactured by: LS Control A/S http://www.lscontrol.com Phone: +45 5550 5550 Drawing: User Manual_ES1047_rev1_UK...
For each compressor, the compressor data from the manufacturer datasheet must be hard wired into the frequency converter software by LS Control. Afterwards the specific compressor is selected by means of dip switches. Since the compressor parameters change with changing loads, LS Control must carry out a performance test on each individual compressor to select the best parameters covering the widest range of operating patterns ensuring that the compressor will be able to operate at high loads as well as low loads.
Adjustable speed electrical power drive systems - Part 5-1: Safety requirements - Electrical, thermal and energy. If a frequency converter is purchased without enclosure (IP00), LS Control cannot ensure that the frequency converter complies with the above standards. Warnings Before the frequency converter is taken into use, verify that the frequency converter specifications are compatible with the mains to which it is going to be connected.
Page 5
EMC compliance. The frequency converter is sensitive to ESD (ElectroStatic Discharge). Handle with care. ESD may cause damage to the frequency converter. Page 5 • LS Control A/S • Industrivej 12 • DK –4160 Herlufmagle • Tel: +45 5550 5550 •...
Should the temperature continue to increase, despite the speed reduction, the frequency converter will stop and indicate error. The temperature reduction function is part of the intelligent Page 6 • LS Control A/S • Industrivej 12 • DK –4160 Herlufmagle •...
Make sure that the mounting surface can withstand the temperature of the surface of the frequency converter. Page 7 • LS Control A/S • Industrivej 12 • DK –4160 Herlufmagle •...
Protective Earthing conductor for motor Motor Conductor U Motor Conductor V Motor Conductor W Shield Grounding from gland Page 8 • LS Control A/S • Industrivej 12 • DK –4160 Herlufmagle • Tel: +45 5550 5550 • Fax:+45 5550 2265 • www.lscontrol.dk •...
Function, and that it will not be able to continue until the Supply Voltage has been removed long enough for the Frequency Converter to completely turn off and on again. Page 10 • LS Control A/S • Industrivej 12 • DK –4160 Herlufmagle •...
Thermal error. Thermal switch is open or thermister is indicating too high a temperature. 16384 Modbus Heartbeat Error Page 11 • LS Control A/S • Industrivej 12 • DK –4160 Herlufmagle • Tel: +45 5550 5550 • Fax:+45 5550 2265 •...
Contact your local authorities for further information on disposal of equipment under the WEEE directive. Page 12 • LS Control A/S • Industrivej 12 • DK –4160 Herlufmagle • Tel: +45 5550 5550 • Fax:+45 5550 2265 •...