CAMBRIDGE CSW-10AT-B Installation And Operation Manual page 9

Digital weight indicator
Table of Contents

Advertisement

S11 Zero Delay
S12 Zero Tracking
S13 Tracking Delay
S14 Lb/Kg (Lb/KG): Allows the indicator to be switched between pounds
S15 Scale ID
S16 Brightness
S17 Sleep Mode
END
( ) indicates Factory Set defaults.
CAMBRIDGE SCALE WORKS, INC.
2.3 Scale Menu Definitions Continued:
0 to 99 updates (4) the weight display must be within
the zero band for the selected number of updates to
be considered Zero.
1 to 99 divisions (2) the number of graduations
allowed to be Automatically Zeroed off.
0 to 99 [15second increments] (10) the amount of
time the display must be within the allowed
graduations before it will be automatically Zeroed.
and kilograms by pressing the lb/kg key.
LB: This sets the display to Pounds only.
Kg: This sets the display to Kilograms only.
(1) to 99 scale ID used in RF link output.
0 to (15) adjusts the LED display intensity 15 is
the brightest.
0 to 30 minutes (20). The display will turn off after the
the set amount of time elapses with no scale activity.
Exits back to the main Menu.
9
Manual P/N 5999-1011-02

Advertisement

Table of Contents
loading

Table of Contents