FUEL TYPE:
The following instructions are for Natural Gas configured grills ONLY. Operating Pressure = 4" WC.
BUILT IN NATURAL GAS HOOK-UP: (Fig. 9)
1. The piping up to the gas grill is the responsibility of the installer and piping should be located as shown below.
2. Use only the natural gas hose supplied with your Natural Gas configured grill.
3. Install the supplied hose onto the flare nut nipple on the fuel regulator, located on the RH inner side of the
pedestal. DO NOT USE SEALANT of any kind. Tighten using a ¾" open end wrench or a crescent wrench.
Hold the regulator nut with a second wrench while tightening.
4. A female quick release (Hansen plug) is included with the grill. Install it onto the homeowner's preexisting
natural gas quick release box. NOTE; pipe dope or Gas Rated Teflon tape must be used to seal the threads
at this connection.
5. The connector must not pass through a wall, floor, ceiling or partition, and is protected from damage.
6. Do not use a hose to connect the unit except
to connect the cylinder regulator to the
piping system.
7. The gas supply pipe must be sufficiently
sized to supply the BTU/h specified on the
rating plate, based on the length of the
piping run.
8. If installing a side burner, a spate line must
be branched off to the side burner unit and
enter the side burner opening at the
specified location.
'
1 Never insert any foreign objects in the quick release or Natural Gas hose, as this may cause
leaks.
2 Pressure from the gas source for this grill MUST NOT exceed 4 inches of Water Column;
using a grill at higher pressures could result in property damage, and injury or death.**
3 Do NOT use this grill until leak tests have been completed.
4. If a gas leak is detected and cannot be stopped, call the fire department immediately
** NOTE; this is the maximum inlet pressure rating for the included Natural Gas Regulator,

Natural Gas Connection:

!WARNING!
part number JF-99
Figure 9
Typical Natural Gas Connection