11-6 REFRIGERATION CYCLE
Troubleshooting Chart
CAUSE
PARTIAL
Freezer
LEAKAGE
compartment and
Refrigerator don't
cool normally.
COMPLETE
Freezer
LEAKAGE
compartment and
Refrigerator don't
cool normally.
PARTIAL
Freezer
CLOG
compartment and
Refrigerator don't
cool normally.
Freezer
WHOLE
compartment and
CLOG
Refrigerator don't
cool.
MOISTURE CLOG
Cooling operation
stops periodically.
COMP-
Freezer and
RESSION
Refrigerator don't
cool.
NO COMP-
No compressing
RESSION
operation.
11-6-1 Cleaning
There is no need for routine condenser cleaning in normal Home operating environments. If the environment is
particularly greasy or dusty, or there is significant pet traffic in the home, the condenser should be cleaned
every 2 to 3 months to ensure maximum efficiency.
If you need to clean the condenser:
Remove the mechanical cover.
Use a vacuum cleaner with a soft brush to clean the grille, the open areas behind the grille and the front
surface area of the condenser.
Replace the mechanical cover.
STATE OF
STATE OF THE
THE UNIT
EVAPORATOR
Low flowing sound of
Refrigerant is heard
and frost forms in
inlet only.
Flowing sound of
refrigerant is not
heard and frost isn't
formed.
Flowing sound of
refrigerant is heard
and frost forms in
inlet only.
Flowing sound of
refrigerant is not
heard and frost isn't
formed.
Flowing sound of
refrigerant is not
heard and frost melts.
Low flowing sound of
refrigerant is heard
and frost forms in
inlet only.
Flowing sound of
refrigerant is not
heard and there is
no frost.
TEMPERATURE
OF THE
COMPRESSOR
A little higher than
ambient
temperature.
Equal to ambient
temperature.
A little higher than
ambient
temperature.
Equal to ambient
temperature.
Lower than ambient
temperature.
A little higher than
ambient
temperature.
Equal to ambient
temperature.
- 86 -
REMARKS
• Refrigerant level is low due
to a leak.
• Normal cooling is possible by
restoring the normal amount
of refrigerant and repairing
the leak.
• No discharging of
Refrigerant.
• Normal cooling is possible by
restoring the normal amount
of refrigerant and repairing
the leak.
• Normal discharging of the
refrigerant.
• The capillary tube is faulty.
• Normal discharging of the
Refrigerant.
• Cooling operation restarts
when heating the inlet of the
capillary tube.
• Low pressure at high side of
compressor due to low
refrigerant level.
• No pressure in the high
pressure part of the
compressor.