Valor cosyflame turbochim br528 Owner's Manual

Rear fan flued inset gas fires with live fuel effect

Advertisement

Quick Links

O
W
N
( I n c o r p o r a t i n g
This Owner Guide is intended to help you care for your Valor gas fire.
Please read carefully before using your gas fire and keep for future reference.
This Owner Guide gives sufficient details to enable your gas fire to be operated and
Please keep your Owner Guide in a safe place together with the
E
R
G
V A L O R C O S Y F L A M E
T U R B O C H I M
( M O D E L B R 5 2 8 )
V A L O R S E C R E T
T U R B O C H I M *
( M O D E L
H E A R T H M A S T E R
( M O D E L
R e a r F a n F l u e d
I n s e t G a s F i r e s
w i t h L i v e F u e l E f f e c t
*Covered by GB Patent 2.202.622.B
maintained.
IMPORTANT.
Installer Guide.
U
I
D
B R 5 2 7 )
&
B R 5 2 7 W )
B R 5 1 7
B u r n e r )
E
600B398/02

Advertisement

Table of Contents
loading

Summary of Contents for Valor cosyflame turbochim br528

  • Page 1 B u r n e r ) *Covered by GB Patent 2.202.622.B This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep for future reference. This Owner Guide gives sufficient details to enable your gas fire to be operated and maintained.
  • Page 2: Customer Care

    This appliance is for use in the United Kingdom (GB) and the Republic of Ireland (IE) only. Thank you for choosing Valor. All Valor gas fires are designed to meet the most stringent quality, performance and safety requirements to provide our customers with many years’ trouble-free service.
  • Page 3 Please bear this in mind if ever you are considering altering the room. • Contact the Valor Adviceline on 0345 626 341 with any enquiries you may have (Local call rates apply in the United Kingdom).
  • Page 4 Fig. 1...
  • Page 5 If the flames go out, or if for any reason the fire is turned off, always wait at least 3 minutes before attempting to relight. • If this device starts to shut off the gas frequently please get expert advice from the Valor Advice Line on 0345 626341 (local call rates apply in the United Kingdom). •...
  • Page 6: Gas Consumption

    Gas consumption Natural Gas models have a maximum gas input of 6.0kW (Gross) and a minimum gas input at the low setting of 2.2kW (gross). Propane Gas models have a maximum gas input of 6.1kW (Gross) and a minimum gas input at the low setting of 3.6kW (gross).
  • Page 7 Fitting the ceramics Place the front base coal in the burner compartment so that it rests on the ledges at the sides and front. Pull the coal forward so that it is immediately behind the front rim of the burner compartment. (See Fig 4 and 5). Fig.
  • Page 8: General Servicing

    We recommend that all gas appliances, wherever situated, are checked annually by a competent person (In the UK, a CORGI registered installer). • If you require your fire to be serviced, please contact Valor Service on 0121 386 6203. Quote the following details; a) - model name b) - model no c) - appliance serial no.
  • Page 9: Useful Telephone Numbers

    Type of fire. c) Model/Name. d) Serial Number. e) The fault, problem or request. General advice about gas and your gas fire: VALOR ADVICELINE 0345 626341. To report faults or arrange for your fire to be serviced: VALOR SERVICE 0121 386 6203.
  • Page 10 BS EN ISO 9001 quality system accepted by the British Standards Institute. The Highest Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety, quality and performance. Careful Installation Valor is a Corgi registered company.

This manual is also suitable for:

Secret turbochim br527Hearthmaster br527w

Table of Contents