Channel Programming

The OM-CP-RFC1000-EXT transmits data on the 2.4GHz band, channel 11. Each Omega Wireless Data Logger
and OM-CP-RFC1000-EXT has a set of dip switches with which the channel may be programmed.
Any Omega data logger or OM-CP-RFC1000-EXT that is on the same network are required to use the same
channel. If they are not on the same channel, the devices will not communicate with one another.
Different wireless channels may be used to create multiple networks in one area, or to avoid wireless
interference from other devices. The images below show the orientations available of the switches for each
channel. Channel 26 (all switches in the up position) is not supported.
Channel 11
Channel 17
Follow the instructions below to configure the channel settings of the Omega Data Loggers.
OM-CP-RFC1000-EXT: To program the channel on an OM-CP-RFC1000-EXT, first unplug the OM-CP-
RFC1000-EXT. Use a Phillips head screwdriver to unscrew the enclosure. The dip switches are located on
the front of the PCB circuit board. Change the dip switches to match the photo. Reconnect the OM-CP-
RFC1000-EXT.
OM-CP-RFRHTemp2000A: To program the channel on the OM-CP-RFRHTemp2000A data logger, start by
switching the wireless mode to OFF by holding down the Wireless button on the data logger for 5 seconds.
1.
Use the USB Cable, plug the USB end of the cable into an available USB port on the PC.
2.
Plug the opposite end of the cable into the communication port on the OM-CP-RFRHTemp2000A.
3.
Open the Omega data logger Software. Locate and select the OM-CP-RFRHTemp2000A in the Connect
Devices panel.
4.
In the Device tab, click the Properties icon. The Properties screen will display information about the
device including Wireless setting.
5.
Under the Wireless tab, select a desired channel (11-25) that will match with the OM-CP-RFC1000-EXT.
Save all changes, disconnect the data logger, and return the device to wireless mode by holding down
the Wireless button for 5 seconds.