KV-29FS12A
Handling of Self-Diagnostic Screen Display
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during repairs.
When you have completed the repairs, clear the result display to "0".
Unless the result display is cleared to "0", the self-diagnostic function will not be able to detect subsequent faults after completion of the
repairs.
Clearing the Result Display
To clear the result display to "0", press buttons on the Remote Commander sequentially when the diagnostic screen is displayed,
as shown below:
Channel 8
ENTER
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.
Self-Diagnostic Circuit
MA BOARD
Y/CHROMA JUNGLE
FROM
36
IK IN
CA BOARD
CN705 PIN 1
FROM
33
HP/PROTECT
A BOARD
IC501 PIN 3
+B overcurrent (OCP)
I-Prot
IK
A BOARD
IC301
IC502
V. OUT
REF
3
61
SDA
Occurs when an overcurrent on the +B (135V) line is detected by pin 33 of IC301 (MA Board). If
the voltage of pin 33 of IC301 (MA Board) is less than 1V when V.SYNC is more than seven
verticals in a period, the unit will automatically turn off.
Occurs when an absence of the vertical deflection pulse is detected by pin 5 of IC001 (MA
Board). Power supply will shut down when waveform interval exceeds 2 seconds.
If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be
detected by IC301 (MA Board). TV will stay on, but there will be no picture.
*(Refers to the RGB levels of the AKB detection Ref pulse that detects 1K).
MA BOARD
IC001
SYSTEM
IO-BDAT
42
5
I-PROT
O-LED
22
43
IO-SDAT
— 6 —
MA BOARD
IC003
MEMORY
5
B-DAT
DISPLAY