Errors In Operate Mode; Errors In Tx/Rx Mode; Warnings In Operate Mode - REIMESCH KOMMUNIKATIONSSYSTEME GMBH ALPIN 100 MK III User Manual

Hf / 50mhz linear amplifier
Table of Contents

Advertisement

3 PROTECTION SYSTEM

3.3. Errors in Operate mode:

Code
49
50
51
52

3.4. Errors in TX/RX mode:

Code
64
66
67
68

3.5. Warnings in Operate mode:

Besides those errors there are some warnings in the Operate mode. The amplifier shows a
flashing warning message and/or will switch to Standby mode.
Message
REFLECTED PWR
DRIVE TOO HIGH
SCREEN CURRENT
PLATE CURRENT
OVERHEATING
ARC FAULT
GRID CURRENT
ALPIN100 Manual © Copyright 2010 by Reimesch Kommunikationssysteme GmbH
plate current > 1.2 A
problem in low voltage supply
HV > 3300V or HV < 1500V
problem with output relay contact
output relay contact switch 5ms problem
output relay contact switch 5ms problem
Grid RF and PANT are not ok
Legend
Reflected power > 350W
Drive power > 90W for less than 5 s
Drive power > 90W for more than 5s
Drive power > 120W
Screen current > 80mA for more than 1s
Plate current > 700mA
Plate current > 800mA for more than 2s
Temperature > 97°C ( 207° F)
Temperature > 115°C ( 239° F)
Recognized arc
Grid current too high
Legend
low air for > 90 s
Legend
16
Action
Standby mode
Warning
Standby mode
Standby mode
Standby mode
Warning
Standby mode
Warning
Standby mode
Standby mode
Standby mode

Advertisement