Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.
!
WARNING
To reduce the risk of fire, electrical shock, or
personal injury, mount fan to outlet box marked
"Acceptable for Fan Support", and use screws
supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if
in doubt.
If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.
How to Put Your Ceiling Fan Together
1. Rotate the motor hub to align the hub motor area
over each of the five shipping retainers. One by
one unscrew each of the five screws and discard
screws and shipping retainers (Figure 1).
SWITCH HOUSING
ADAPTER
REMOVE AND DISCARD
THE FIVE SHIPPING
SPACERS AND SCREWS
FROM THE MOTOR HUB
Figure 1
2. Mount blade flanges to fan blades using three M5 x
6mm washer head blade screws (Figure 2).
NOTE: Take care not to scratch fan housing when
installing blades.

Electrical Requirements

4
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before attempting
installation. All wiring must be in accordance with
National and Local codes and the ceiling fan must be
properly grounded as a precaution against possible
electrical shock.
WARNING
!
To avoid fire or shock, follow all wiring instructions
carefully. Any electrical work not described in these
instructions should be done or approved by a
licensed electrician.
M5 x 6mm WASHER
HEAD BLADE SCREW
(3 per blade/flange)
BLADE FLANGE
Figure 2
3. Loosely attach one blade/flange assembly to the
motor hub by securing the two M6 x 14mm captive
pan head screws. Make sure the screws are NOT
tightened (Figure 3). Repeat this procedure for
other four blade assemblies.
!
WARNING
To reduce the risk of personal injury, do not bend the
blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.
FAN BLADE
U.L. Model No.: CF452