Output Capacity - Fedders Herrmidifier Mister 50 User Manual

Duct mount atomizing humidifier
Table of Contents

Advertisement

Output Capacity

Output Capacity
Increasing or decreasing the nozzle size or
water pressure to the humidifier can vary the
output capacity of this humidifier. It is
recommended that the humidifier not be
used at water pressures below 40 PSI,
otherwise, the mist may be affected.
The following chart illustrates the capacity of
different nozzles at varying water pressures.
The output capacities shown are for water,
and are 1/2 the output capacity of the rated
oil nozzles. 1.00 oil = .50 water
Oil Nozzle
size
.37
.50
.75
1.0
Oil Nozzle
size
.37
.50
.75
1.0
This humidifier comes standard with a hollow
cone pattern .75 GPH nozzle, however,
additional nozzles may be purchased from
your local plumbing distributor or hardware
store. If the water pressure fluctuates or is
excessive, a small pressure regulator should
be installed in the water line supplying the
humidifier.
WATER PRESSURE
40 PSI
GPH
GPD
.185
4.44
.250
6.00
.375
9.00
.500
12.00
WATER PRESSURE
80 PSI
GPH
GPD
.275
6.60
.350
8.40
.550
13.20
.700
16.80
3
Note:
Due to the operation cycle of the
furnace and humidifier, it may take
anywhere from 2 to 5 days to reach
the proper humidification level.
50 PSI
GPH
.225
.300
.445
.600
100 PSI
GPH
.300
.400
.600
.800
GPD
5.44
7.20
10.68
14.40
GPD
7.20
9.60
14.40
19.20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Herrmidifier mister 50-1

Table of Contents