Fedders AC1A024A Installation, Operation And Maintenance Manual
Fedders AC1A024A Installation, Operation And Maintenance Manual

Fedders AC1A024A Installation, Operation And Maintenance Manual

Cased evaporator coils upflow/downflow

Advertisement

Quick Links

Installation, Operation and Maintenance
Cased Evaporator Coils
Upflow/Downflow

TABLE OF CONTENTS

NOTES TO INSTALLER ....................................................................2
INTRODUCTION ..............................................................................3
INSPECTION AND UNPACKING ......................................................3
Codes..................................................................................2
Installation of Evaporator Coils........................................3
Connect Refrigerant Piping ..............................................3
Condensate Drain Plumbing ............................................4
Heater Exchange Clearance..............................................4
CHECK AND ADJUST AIRFLOW ....................................................5
Static Pressure Drop Chart ................................................5
Adjusting Airflow ..............................................................5
COIL NOMENCLATURE ..................................................................6
SPECIFICATIONS..............................................................................6
DIMENSIONS ..................................................................................6
WARRANTY ....................................................................................7
NOTE:
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED
SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT
AND OPERATION OF THIS EQUIPMENT. READ THE ENTIRE
INSTRUCTION MANUAL THOROUGHLY BEFORE ATTEMPTING
INSTALLATION OR OPERATION.
1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AC1A024A and is the answer not in the manual?

Questions and answers

Summary of Contents for Fedders AC1A024A

  • Page 1: Table Of Contents

    Installation, Operation and Maintenance Cased Evaporator Coils Upflow/Downflow TABLE OF CONTENTS RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS ...2 NOTES TO INSTALLER ...2 INTRODUCTION ...3 INSPECTION AND UNPACKING ...3 INSTALLATION Codes...2 Installation of Evaporator Coils...3 Connect Refrigerant Piping ...3 Factory and Field Installed Expansion Valves ...3 Condensate Drain Plumbing ...4 Heater Exchange Clearance...4 CHECK AND ADJUST AIRFLOW ...5...
  • Page 2: Recognize Safety Symbols, Words And Labels

    RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS What You Need To Know About Safety Instructions Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment.
  • Page 3: Introduction

    CABINET WITH INSULATION. Installation of Evaporator Coils The cased coil is designed to fit Fedders furnaces the same width. Set coil on upflow furnace discharge air opening. Ensure coil is level for proper condensate drainage. Do not tip coil toward condensate drain.
  • Page 4: Condensate Drain Plumbing

    Factory and Field-Installed Expansion Valves (cont.) To assure accurate sensing and the best performance, the bulb should be placed on the upper half of the vapor line at the four or eight o’clock position and at least 6” from the coil manifold. WARNING ALWAYS HAVE A FIRE EXTINGUISHER AVAILABLE WHEN WORKING WITH AN OPEN FLAME.
  • Page 5: Check And Adjust Airflow

    See chart below. MODEL INDOOR THROUGH DRY COIL* & HOUSING (INCHES WATER COLUMN / CFM) CASED COILS 600 700 900 1000 1100 1200 1300 AC1A024A AC1A030A AC1A036A AC1A042A AC1A060A Adjusting Air Flow If gauge reading is below the required pressure, increase blower speed until reading is the same or slightly above the required pressure.
  • Page 6: Coil Nomenclature

    1 = Upflow/Downflow Design Series A = A Series COIL NOMENCLATURE A C 1 A 036 A 14 Brand Coil A = Fedders Coil Case Designation C = Cased Coil Position 1 = Upflow/Downflow Design Series A = A Series...
  • Page 7: Warranty

    LIMITED WARRANTY LIMITED FIVE YEAR WARRANTY: Fedders will provide a replacement part or component that proves to be defective in material or workmanship. WARRANTY LIMITATIONS: • Limited Warranty does not include allowances for labor or travel expense connected with the installation of...
  • Page 8 Illustrations cover the general appearance of the units at the time of publication and the manufacturer reserves the right to make changes in design and construction at any time without notice. For replacement parts please, consult the installing dealer or contractor. Fedders Corporation 505 Martinsville Rd. Liberty Corner, NJ 07938 REV.

This manual is also suitable for:

Ac1a036aAc1a030aAc1a042aAc1a060a

Table of Contents