Connecting The Ethernet Cables - Cisco uBR905 Installation Manual

Cable access router
Table of Contents

Advertisement

Chapter 3
Installing the Cisco uBR905 Router
Figure 3-1
To cable source
Caution
Do not overtighten the connector because this can break off the connector. Using a torque
wrench is not recommended because of the danger of tightening the connector more than
the recommended 1/6 turn after it is finger tight.
Make sure that all other coaxial cable connectors—all intermediate splitters, couplers, or ground
Step 5
blocks—are securely tightened from the distribution tap to the Cisco uBR905 router, following
instructions in Step 4.
Loose connectors inside the building or residence can cause intermittent router operation.
Note
Caution
To ensure compliance with FCC limits, connection to the cable system must be made with
a high-quality, shielded cable. If the quality or general condition of the coaxial cable at the
subscriber site is in question, Cisco recommends that you replace the coaxial cable. For
more information on the effects of substandard cabling on the cable access router
installation, see the "CATV Coaxial Cabling" section on page 2-5.

Connecting the Ethernet Cables

To connect the Cisco uBR905 router to computers and other CPE devices at the site:
Step 1
Locate all needed 10BaseT RJ-45 Ethernet cables:
OL-0598-01 (9/2000)
Connecting the CATV Coaxial Cable to the Cisco uBR905 Router
1
Cabl e TV In
X
F connector
(Cable TV In)
Use straight-through Ethernet cables to directly connect up to four PCs to the Cisco uBR905 cable
access router's four Ethernet hub ports.
Ethe rnet 0
2
3
4
X
X
X
Cons ole
Rese t
Cisco uBR905 Router Hardware Installation Guide

Connecting the Ethernet Cables

Cisc o uBR 905
Powe r
5V
3-5