PRATICAL ADVICE FOR USING THE BURNERS
This hob has burners of different diameters. For better burner performance,
please stick to the following rules:
-
Use pots and pans with bottoms the same width as that of the burners or
slightly larger (see table on the right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and keep the pot
covered.
-
Make sure pots on the grates do not protrude beyond the edge of the hob.
IMPORTANT: improper use of the grids can result in damage to the hob: do
not position the grids upside down or slide them across the hob.
Do not use:
-
Cast iron griddles, ollar stones, terracotta pots and pans.
-
Heat diffusers such as metal mesh, or any other types.
-
Two burners simultaneously for one receptacle (e.g. fish kettle).
HOW TO USE THE HOB
Do not let the burner flame extend beyond the edge of the pan.
WARNING
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting.
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit,
wait at least one minute before trying to light it again.
NOTE: should particular local conditions of the delivered gas make the ignition of burner difficult, it is advisable to repeat
the operation with the knob turned to small flame setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this
case, repeat the operations described above.
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE: in case of installation of a hood above the cooktop,
please refer to the hood instructions for the correct
distance.
INJECTORS TABLE
Burner
Pot Ø
Type of gas used
Rapid
From 24 to 26 cm
Semi-rapid
From 16 to 22 cm
Auxiliary
From 8 to 14 cm
NATURAL GAS
(Methane)
LIQUEFIED
PETROLEUM GAS
(Cylinder) G30/G31
Type of gas used
G20 20 mbar
G30/G31 30 mbar
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Type of burner
Injector
Rated thermal
marking
flow rate
kW
Rapid
129 B
3.00
Semi-rapid
97
1.65
G20
Auxiliary
74 B
1.00
Rapid
86
3.00
Semi-rapid
65
1.65
Auxiliary
50
1.00
Model
Rated thermal
configuration
flow rate (kW)
4 burners
7.30
4 burners
7.30
CATEGORY II2H3B/P
Rated
Reduced heat
Gas pressure
consumption
capacity
mbar
kW
min. rat. max.
286 l/h
0.60
157 l/h
0.35
17
20
25
95 l/h
0.30
218 g/h
0.60
120 g/h
0.35
20
30
35
73 g/h
0.30
3
Total rated
Air required (m
) for
3
consumption
burning 1 m
of gas
695 l/h
9.52
531 g/h
30.94