Desa (V)K36N SERIES Owner's Operation And Installation Manual page 22

Direct-vent fireplace
Hide thumbs Also See for (V)K36N SERIES:
Table of Contents

Advertisement

OPERATING FIREPLACE
Continued
11. This valve is equipped with a HI/LO feature. Set fireplace
input as desired.
12. Close lower louver panel.
Gas Control
Knob
Piezo
Ignitor
Figure 49 - Control Valve
TO TURN OFF GAS
tO APPLIANCE
1. Open lower louver panel.
2. Set selector switch in the OFF position to prevent draining
battery.
3. Turn off all electrical power to the appliance if service is to
be performed.
4. Push in gas control knob slightly and turn clockwise
to OFF.
5. Close lower louver panel.
Shutting Off burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing
one of the following:
1. Turn gas control knob clockwise
position.
2. Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see Removing/Replacing Glass Door,
page 19.)
2. Follow steps 1 through 8 under Lighting Instructions,
page 21.
3. Depress gas control knob and light pilot with match.
4. Keep gas control knob pressed in for 30 seconds after light-
ing pilot. After 30 seconds, release gas control knob. Follow
steps 9 through 12 under Lighting Instructions, page 21.
5. Replace glass door (see Removing/Replacing Glass Door,
page 19).
22
Variable Control Knob
to the PILOT
www.desatech.com
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased sepa-
rately (see Accessories, page 29). Follow instructions included
with the remote control.
NOtICE: You must light the pilot before using the
hand-held remote control unit. See Lighting Instruc-
tions, page 21.
After lighting, let pilot flame burn for about one minute. Turn
control knob to ON position. Adjust flame adjustment knob
anywhere between HI and LO. Slide the selector switch to the
REMOTE position (see Figure 50). Note: The burner may light
if hand-held remote was on when selector switch was last turned
off. You can now turn the burner on and off with the hand-held
remote control unit.
IMPORTANT: Do not leave the selector switch in the REMOTE
or ON position when the pilot is not lit. This will drain the
battery.
Blower Control Knob
(Optional Accessory)
Selector Switch in
Remote Position
Figure 50 - Setting the Selector Switch, Gas Control Knob
and Variable Control Knob for Remote Operation
ON/OFF SERIES MODEL HRC100
Hold the control button on the hand-held remote until burner
turns on. Hold the control button again until burner turns off
(see Figure 51).
tO LOCK press both buttons on hand-held remote control until
light stops flashing. Hand-held remote control is now locked. If
the fire is on it will be turned off automatically. In the locked
state, the light will not light up when any button is pressed.
tO UNLOCK press both buttons together on hand-held remote
control until the light stops flashing. The hand-held remote is
now unlocked.
Indicator
Light
Figure 51 - On/Off Hand-Held Remote Control Unit HRC100
Variable
Control Knob
OFF
ON
Gas Control Knob
in ON Position
Control
Button
111923-01D

Advertisement

Table of Contents
loading

This manual is also suitable for:

(v)k36p series