Desa (V)K36N SERIES Owner's Operation And Installation Manual page 18

Direct-vent fireplace
Hide thumbs Also See for (V)K36N SERIES:
Table of Contents

Advertisement

FIREPLACE INSTALLATION
Continued
3. Check all joints from propane/LP supply tank or gas meter to
equipment shutoff valve (see Figure 34 or 35). Apply noncor-
rosive leak detection fluid to all joints. Bubbles forming show
a leak. Correct all leaks at once.
Equipment
Propane/LP
Shutoff
Supply Tank
Valve
Figure 34 - Checking Gas Joints for Propane/LP Gas
Equipment
Shutoff
Valve
Gas
Meter
Figure 35 - Checking Gas Joints for Natural Gas Fireplace
PRESSURE tEStING FIREPLACE GAS CONNECtIONS
1. Open equipment shutoff valve (see Figure 33, page 17).
2. Open propane/LP supply tank valve for propane/LP fireplace
or main gas valve located on or near gas meter for natural gas
fireplace.
3. Make sure control knob of fireplace is in the OFF position.
4. Check all joints from equipment shutoff valve to gas valve (see
Figure 34 or 35). Apply noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct all leaks at once.
5. Light fireplace (see Operating Fireplace, page 21). Check all
other internal joints for leaks.
6. Turn off fireplace (see To Turn Off Gas to Appliance, page 22).
18
Gas Valve
Fireplace
Gas Valve
INSTALLING OPTIONAL WALL MOUNT
SWItCH - GWMS2
1. Connect one terminal of 25 ft. wire for wall switch to the TPTH
terminal on valve. Connect remaining wire terminal to TH
terminal on valve. Make sure wire terminals are in positions
on unit as pictured in Figure 36. If wires are not connected as
shown, switch will not work.
2. Route 25 ft. wire through openings provided on sides of burner
system to a convenient location to mount switch.
3. Connect one bare wire end to each of the terminals of the
GWMS2 wall switch.
4. Install wall switch and cover in wall.
Figure 36 - Connecting Wall Switch to Control Cover
INSTALLING OPTIONAL WIRELESS HAND-
HELD REMOtE CONtROL - HRC100 AND
HRC200 SERIES
NOtICE: Use only alkaline batteries (not included).
Installing Remote Receiver
1. Open bottom louver and locate the switch bracket on the left.
2. Unscrew the switch bracket. Lean bracket forward so you are
able to access the back of the remote receiver.
3. Locate the battery clip mounted on the back of the receiver.
Slide a 9-volt alkaline battery (not included) through the clip
(see Figure 37).
4. Attach the terminal wires to the battery.
5. Connect wires from receiver to TH and TPTH to control valve
(see Figure 38).
6. Replace the switch bracket.
Receiver
9-Volt
Alkaline
Battery
Figure 37 - Attaching Alkaline Battery to Receiver
To Optional
Remote
Accessory
Figure 38 - Control Valve Terminals
www.desatech.com
Battery Clip
To Wall
Thermostat
Terminal
Wires
111923-01D

Advertisement

Table of Contents
loading

This manual is also suitable for:

(v)k36p series

Table of Contents