9.1.4 DEFINITION OF COMMAND

Single functional command
The command to which operation is concluded only by command. The command parts are 3 characters.
A
Adjustment command and adjustment value
• The command to which value of parameter is changed attended with adjustment value.
The command parts are 3 characters.
• The adjustment value is the numeric character data of the decimal number 3 characters.
It is made the range of 000-999. The range that can be adjusted is different according to the function to adjust (It is
noted that then, it is not uniformly to 999).
B
Send data to
STX
0x02
* When the received command exceeds the range where the adjustment value can be adjusted, "XXX" is transmitted.
* When the same adjustment value is continuously transmitted two times or more, "XXX" doesn't reply, though it is an
invalid command. It's overwrited, and ACK that deletes ID replies.
Set command and Set value
C
• The command to which set value of parameter is changed attended with set value.
The command parts are 3 characters.
• Set values are three characters. The first character is fixed to "S".
2 remainder characters are assumed to be assumption S00-S99 as the decimal number.
Send data to
STX
0x02
* When the received command doesn't exist as a set value, "XXX" is transmitted.
* When the same set value is continuously transmitted two times or more, "XXX" doesn't reply, though it is an invalid
D
command. It's overwrited, and ACK that deletes ID replies.
State acquisition command
• The command that reports on state of operation and set value, etc. to system side.
• The content that corresponds by the kind of the command is read from the memory, when the command is received
from the system side and it replies.
• The command parts are three characters. The first character is fixed to "Q". It sets since the second character according
to the content of information.
• The reply data is transmitted adding various data that converts the received command and ASCII code and the checksum
of the data. Because the content of the reply changes according to the kind of the "QUEST command", the data length
follows an individual, individual specification.
E
Send data to
STX
0x02
F
158
1
2
Send data to
PC
STX
ID
Command
∗∗
0x02
PON
PC
ID
Command
Parameter
∗∗
CNT
128
PDP system
ID
Command
Parameter
∗∗
MKS
S02
PDP system
ID
Command
ETX
∗∗
QS1
0x03
2
3
Receive data
ETX
STX
0x03
0x02
Receive data
ETX
STX
0x03
0x02
Receive data
ETX
STX
0x03
0x02
Receive data
STX
Command
0x02
PDP-507XD
3
4
Command
ETX
PON
0x03
Command
Parameter
ETX
CNT
128
0x03
Command
Parameter
ETX
MKS
S02
0x03
Parameter
ETX
QS1
• • • • • • • • •
0x03
4