Saab Marine Electronics AB takes no responsibility for any errors that may appear in this manual. As each TankRadar G3 is specially designed for each delivery, the con- tents and illustrations in this manual may differ from your TankRadar G3 system.
Contents Documentation for Saab TankRadar ................. 2 Training ........................... 2 www.saab.tankradar.com ....................2 Abbreviations ................5 System overview ................7 Equipment in the I/O Unit cabinet ...........9 I/O Terminal Analog Input -description ..............9 LED´s ............................... 9 Fuses ................................ 9 I/O Terminal Analog Output - description ............10 LED´s ..............................
Page 4
Service Manual Maintenance ................19 Trouble shooting ..............21 Spare Parts ................23 Recycling of Saab TankRadar...........25 Give us your opinion!..............27 G3 MaC Second edition, March 2000...
Valve control Pump control Safe area system (not system (not Saab supply) Saab supply) Temperature Pressure Valves sensors sensors Hazardous area Cargo or ballast pumps Figure 2-1 An example of a Saab TankRadar MaC system. G3 MaC Second edition, March 2000...
Page 8
Service Manual G3 MaC Second edition, March 2000...
3 Equipment in the I/O Unit cabinet Equipment in the I/O Unit cabinet I/O Terminal Analog Input - description Figure 3-1 above. The large type of I/O Unit. Figure 3-2 right. The I/O Terminal Analog Input. Fuse LED, power Connector (Power and Communication) LED, ground Failure LED, communication Address Switches...
Service Manual I/O Terminal Analog Output - description Figure 3-3 The I/O Terminal Analog Output. Fuse LED, power Connector (Power and Communication) LED, ground Failure LED, communication Address Switches Jumpers (channel settings) Channel Switches (connected/disconnected) Cable terminal LED´s Power (green) The lit LED indicates that the terminal has power.
3 Equipment in the I/O Unit cabinet I/O Terminal Digital Input - description Figure 3-3 The I/O Terminal Digital Input. LED, power Connector (Power and Communication) LED, ground Failure LED, communication Address Switches Channel Switches (connected/disconnected) Cable terminal LED´s Power (green) The lit LED indicates that the terminal has power.
Service Manual I/O Terminal Digital Output - description Figure 3-3 The I/O Terminal Digital Output. LED, power Connector (Power and Communication) LED, communication Address Switches LED, relays Cable terminal LED´s Power (green) The lit LED indicates that the terminal has power.
Terminal Main Block turns off the power in the I/O Unit. In the Saab TankRadar I/O Unit, turn off the power by turning the automatic fuse switch on the I/O Terminal Main Block to the off position. Disconnect the connector (power and communication) from the terminal.
Service Manual Connect the connector (power and communication) to the terminal. Turn on the power on the I/O Terminal Main Block. Power supply in I/O Unit - description Led, Power Figure 3-5 The Power Supply in the I/O Unit. LED´s DC ON (green) The lit LED indicates that the Power is on...
3 Equipment in the I/O Unit cabinet Power supply in I/O Unit - service To replace a Power Supply In the Saab TankRadar I/O Unit, turn off the power by turning the automatic fuse switch on the I/O Terminal Main Block to the off position.
Service Manual I/O Terminal Main Block - description Figure 3-7 The automatic fuse switches on the I/O Terminal Main Block turns off the power in the I/O Unit. Automatic fuse Fuse The I/O Terminal Main Block have two automatic fuses that also are used to shut down the I/O Unit.
Verify the configuration of the address switches by compar- ing with the old motherboard. Put the old terminal in an ESD protection bag for transport to Saab Marine Electronics. Mount the board in the box. Connect the cables to the cable terminal.
Trouble shooting Symptom Cause Action WS Alarm- Ground failure on In the Saab TankRadar I/O Unit , Warning, IO terminal Bus (1-4) gnd one terminal identify the terminals with a lit fail red ground failure LED Check the equipment (pumps,...
Page 22
Check if the power supply is functioning Check cabling Replace the Power Supply Broken circuit In the Saab TankRadar I/O Box, between I/O Unit check the communication LED on the RS-485 PCB Refer to as- and I/O Box built drawings to find right PCB...
7 Spare Parts Spare Parts Spare parts are ordered from Saab Marine Electronics’ After Sales department Part No. Spare part 0980 239-008 Fuse 500 mA 9240 006-801 I/O Terminal Analog Input 9240 006-802 I/O Terminal Analog Output 9240 006-803 I/O Terminal Digital Input...
Page 24
Service Manual G3 MaC Second edition, March 2000...
Recycling of Saab TankRadar At a point in time when your Saab TankRadar system has served you well for many years and it is time to scrap the ship Saab Marine Electronics is more than willing to assist you with the recycling of the system.
Page 26
Service Manual G3 MaC Second edition, March 2000...
Give us your opinion! To produce the best possible product. We design Saab TankRadar in cooperation with you, our customers. We are therefor always interested in hearing your opinion. Please contact us and tell us what you think of this manual and the Saab TankRadar system.