Direct Steam Wall Mount Tilting Kettles

Installation

Unpacking
Immediately after unpacking the steamer, check for possible shipping damage. If the steamer is found to be damaged,
save the packaging material and contact the carrier within 15 days of delivery.
Prior to installation, verify that the type of gas supply (natural or propane) and electrical service agree with the
specifications on the rating plate located on the left side panel as you face the front of the braising pan. If the supply
and equipment requirements do not agree, contact your dealer immediately.
Installation
1. The kettle must be installed in accordance with state and/or local codes.
2. Prepare wall for kettle installation.
3. Each console is to be supported with three, 3/4 inch diameter bolts, studs or equivalent, to the supporting
structure. Ensure the supporting structure is capable of the load requirements and meets the local codes
and standards. Wall and above mounting hardware must be capable of carrying three times the weight of the
loaded kettle. See table for approximate loaded kettle weight.
4. Bolt kettle in place through the installation holes in console to the wall.
5. Re-check kettle is level, side to side and front to back.
6. Apply sealant around the console perimeter on the wall. Wipe off excess sealant immediately.
7. Connect steam line (3/4" pipe size) to the kettle, making sure there is a steam control valve strainer fairly
convenient to the kettle.
8. Connect kettle condensate return line to a drain or to a boiler return line. Each kettle return line must have a
suitable steam trap. Boiler return lines must have a check valve.
9. Safety relief valve on kettle must not be plugged as it is set to relieve excess pressure in the kettle.
10. If incoming steam pressure is greater than kettle maximum operation pressure then a pressure reducing valve
must be installed in the line.
11. If large amounts of water accumulate in the steam line it will be necessary to install one or more ball float traps
in the line to eliminate the water.
12. A steam line pressure gauge is also recommended to determine the actual amount of steam being supplied to the kettle.
13. Check for proper operation.
Kettle Model
DWT-20
DWT-30
DWT-40
DWT-60
DWT-80
DWT-100
INSTALLATION & OPERATION MANUAL 10197 REV 0 (07/21)
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
Weight of Empty Kettle (lb)
334
412
480
539
574
630
Installation
Weight of Fully Loaded Kettle (lb)
334
412
480
539
574
630
PAGE
5
OF12